R-109
QT-6000 Reference Manual
Satellite Master
Ter minal
files
Ter minal
files
Consolidation
work
1
2
3
2
Satellite Master
Ter minal
files
Ter minal
files
Consolidation
work
1, 4
2
3
2
3-6-1. X/Z collection
This function is used to obtain the counters and totals of the individual terminals.
For collection results (normal end or error end), the satellite does not print it out on the
receipt / journal during X collection. But the results of the Z collection are printed out in
the journal during Z collection.
3-6-1-1. X collection processing
X collection processing is performed as the figure shown below.
1 An X collection command is started up from the master terminal.
2 One objected terminal sends its report data to the consolidation work file of the master.
3 Report data from the objected terminal file are printed out on the master's R/J printer.
4 After processing of the master terminal completes, the same processes described in the
item 1 to 3 are executed for the other terminals. Data will be sent without the clerk
noticing, even when the satellite in the process of registering.
3-6-1-2. Z collection processing
Z collection processing is performed as the figure shown below.
1 When a Z collection command is started up from the master terminal, the master first
locks one objected terminal. (Z lock)
2 The objected terminal sends its report data to the consolidation work file of the master
terminal.
3 Report data from the satellite terminal file are printed out on the master R/J printer.
4 The same processes described in the item 1 to 3 are executed for the other terminals.
5 After the processing of the master terminal completes, the data of objected terminal file
are cleared, and then the Z lock of the objected terminal is released.
NOTE:
•When a Z collection is performed, the consolidation data cannot be output. If output of
consolidation data is desired, perform “collection/consolidation” processing described
later.
Even if an error is occurred, or if the processing is terminated, the data to be collected
remains as they are, and Z lock statuses are automatically released.

Table of Contents

Other manuals for Casio QT-6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Casio QT-6000 and is the answer not in the manual?

Casio QT-6000 Specifications

General IconGeneral
Types of paymentCash
Second displayYes
Second display typeLED
Power sourceAC
AC input voltage120-240 V
Power consumption1100 mA
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)20 - 85 %
Weight and Dimensions IconWeight and Dimensions
Depth311 mm
Width343 mm
Height288 mm
Weight5300 g