R-39
QT-6000 Reference Manual
2-3-2. Remote printer control setting
Remote printer settings:
After changing the DIP switch configuration, remote printer initialization (power on by
pressing the <LF> key) is necessary.
SW No. Function
Data reception error
Receive buffer capacity
Handshaking
Data word length
Parity check
Parity selection
Transmision speed
ON OFF
Ignored Prints "?"
45 bytes 4k bytes
XON/XOFF DTR/DSR
7 bits 8 bits
Ye s N o
Even Odd
See transmission
speed setting
Density setting
Light
Dark
SW No.
3
ON
OFF
ON
OFF
4
ON
OFF
OFF
ON
UP-350 Bottom view
DSW1
DSW2
1
2
3
4
5
6
7
8
1
SW No. Function
Busy condition
Reserved
Print density
Reserved
Reserved
I/F 6 pin reset signal
I/F 25 pin reset signal
ON OFF
Buffer full
Buffer full
or Offline
Fixed
See density setting
Fixed
Fixed
Enabled Disabled
Enabled Disabled
1
2
3
4
5
6
7
8
2
Transmission
speed setting
bps
2400
4800
9600
19200
SW No.
7
ON
OFF
ON
OFF
8
ON
ON
OFF
OFF
SW No. Function
Data reception error
Receive buffer capacity
Handshaking
Data word length
Parity check
Parity selection
Baud rate
Busy condition
ON OFF
Ignored Prints "?"
40 bytes 1k byte
XON/XOFF DTR/DSR
7 bits 8 bits
Ye s N o
Even Odd
4800 bps 9600 bps
Buffer full
Buffer full
or Offline
1
2
3
4
5
6
7
8
1
SW No. Function
No. of digits
(7x9 font / 9x9 font)
Internal use
#6 pin reset signal
#25 pin reset signal
ON OFF
42 / 35 40 / 33
digits digits
Enabled Disabled
Enabled Disabled
1
2
3
4
2
Select this option.
UP-250
Dip switch is located at the bottom of the printer.
UP-350
SW No. Function
Reset by DTR
reserved
Protocol
Transmision speed
Parity
undifined
Low power comsumption
undifined
ON OFF
Ye s N o
--- fixed
DTR/DSR XON/XOFF
See transmission
speed setting
See paritysetting
--- ---
Ye s N o
--- ---
SW No.
7
OFF
ON
OFF
ON
UP-360 Bottom view
1
2
3
4
5
6
7
8
9
10
1
Parity setting
Non
Even
Odd
Non
6
OFF
OFF
ON
ON
Transmission
speed setting
bps
4800
9600
19200
38400
SW No.
4
OFF
OFF
ON
ON
5
OFF
ON
OFF
ON
UP-360
Dip switch is located at the bottom of the printer.

Table of Contents

Other manuals for Casio QT-6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Casio QT-6000 and is the answer not in the manual?

Casio QT-6000 Specifications

General IconGeneral
Types of paymentCash
Second displayYes
Second display typeLED
Power sourceAC
AC input voltage120-240 V
Power consumption1100 mA
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)20 - 85 %
Weight and Dimensions IconWeight and Dimensions
Depth311 mm
Width343 mm
Height288 mm
Weight5300 g

Related product manuals