EasyManuals Logo
Home>Casio>Touch terminals>QT-6600

Casio QT-6600 Reference Manual

Casio QT-6600
240 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #45 background imageLoading...
Page #45 background image
R-45
QT-6600 Reference Manual
Shared check tracking processing in one cluster is performed as shown in the figure shown
above.
1 A shared check operation (such as new check or old check etc.) is made at a
terminal.
2 The terminal sends the check number to the check tracking master and the backup
master. The master and backup master turn on the busy status.
3 The master sends back the check data (if the check number exists) or opens a new check
number.
4 A shared check transaction is finalized (by new balance or other finalize key).
5 The terminal sends the check data to the master and the backup master. And the master/
backup master clears the busy status of the check number.
2-4-2. Shared check tracking requirement
The following definition of memory allocation is required in each terminal before you can
perform shared check tracking.
Number of check tracking tables:
For satellite, minimum one, for master, more than the number of estimated open checks
should be defined.
*
*
In case of using the next block
**
, one more check tracking table is consumed.
Number of items/tables (per one item block
**
):
This is not the maximum number of items or functions but the number ordinarily
registered items or functions per one table. If the number of items or functions exceeds
this value during registration, the next block is used automatically for the following
transactions.
**
Number of item blocks:
Ordinarily, the registration requires one item blocksbut in a party for examplemore
items are registered per one table. So it is necessary to define how many item blocks can
be used.
The maximum number of items or functions per one check is defined by the formula:
= (Number of items / tables) × (Number of item blocks (1 ~ 10))
When memory near end and memory end happens during registration, an error occurs.
See section A-5. Error messages of this manual.
2-4-3. Data backup when the master goes down
When the system has the backup master for the check tracking system, registered check
tracking data are stored both master and backup master automatically.
As soon as the system detects master down, the backup master roles as master for the check
tracking system.
(It is necessary to switch to backup master manually. See the System down & Recovery
chapter on page 9 of the installation & down recovery manual.)
When the system has no backup master for the check tracking system or both master and
backup master become down, no more check tracking operation and clerk interrupt
operation can be made.
Satellite
Master
Backup
master
Check
tracking
Check
tracking
1
4
3
25

Table of Contents

Other manuals for Casio QT-6600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Casio QT-6600 and is the answer not in the manual?

Casio QT-6600 Specifications

General IconGeneral
BrandCasio
ModelQT-6600
CategoryTouch terminals
LanguageEnglish

Related product manuals