GB
8
6. Check the water connections and effi-
ciency of the pressure switch valve dur-
ing operation, as well as the flow of con-
densing water (in water-cooled units).
7. Perform at least one blast freezing cycle
(to the SET temperature) and one manu-
al defrosting cycle.
In the event that the appliance or the
remote condensing unit have not been
transported in a vertical position (e.g. on
the back) or have been overturned during
installation works, allow at least 4 hours
before starting up the equipment.
• Inform the customer of the exact purpose
of the appliance, with specific reference
to the use and requirements of the cus-
tomer.
The appliance must be installed and put
into service by a technician authorised
by Castelmac.
2.8 Safety and control systems
• Door microswitch: shuts down fan opera-
tion in the cell when the door is opened.
• General fuses: protect the power circuit
against short circuiting and overloads.
• Compressor heat relay: intervenes in the
event of overloads or operating faults.
• Safety pressure switch: intervenes in the
event of excessive pressure in the refrig-
erant circuit.
• Plug fuses: intervene in the event of over-
pressure or operating fault in the safety
pressure switch (see above).
• Chamber temperature control: operated
by the electronic board by means of a
probe inside the cell.
• Temperature control end defrost cycle:
controlled by the electronic board by
means of the probe in the evaporator.
2.9 Appliance disposal
Demolish and dispose of the machine in
compliance with the regulations applied in
the country of installation, particularly in
regards to refrigerant gas and compressor
lubricant oil.