18
6.1 DATE AND TIME SETTINGS :
PUSH-BUTTON (5)
Set the machine to ON .
Press and hold down push-button 5
for more than five seconds to access the
date and time setting function. Display 16
indicates in sequence the abbrevia-
tions Hr (hours), Mn (minutes), dA (day), Mo
(month) and Yr (year), while display 15
shows their respective settings. To scroll the
abbreviations, press push-button 5.
To modify the settings, use push-buttons 7
and 8 .
6.2 ICE CREAM SURFACE HARDENING
PUSH-BUTTON (6)
Set the machine to ON .
Press and hold down push-button 6 for
more than five seconds to access the sur-
face hardening function (push-button LED
flashes). The compressor is switched on; dis-
play 15 shows the default cycle time.
Set the cycle time (in minutes) by means of
push-buttons 7 and 8 . Open the
cell door, place the product inside, then shut
the door to start the cycle. All LEDs remain
off, with the exception of the Start LED. When
the cycle time has elapsed, an acoustic sig-
nal is given. The appliance remains on,
ready for another ice cream hardening cycle.
Open the cell door, remove the hardened
product, replace it, then shut the door. The
machine will perform another hardening
cycle for the time set for the previous one.
Every time the door is opened and closed
after a cycle, the time is reset.
To exit the function, press push-button 6
ADDITIONAL FUNCTIONS
6.3 MUTING THE BEEPER AND ALARM
RESET : PUSH-BUTTON (8)
Press push-button 8 to mute the alarm
beeper.
Alarms are reset :
• by pressing push-button 8 when
the beeper is off;
• automatically if alarm conditions are
removed;
see also section 7 (Alarm Management).
6.4 PROGRAM STORAGE:
PUSH-BUTTON (9)
The programming function is used for cycles
for processing products with the same char-
acteristics. Up to 99 programs can be
stored. Select the type of chilling process
(Soft, Hard, Timed Freezing or by
Temperature), then press and hold push-but-
ton
9
until display 16 shows the
abbreviation P1 (push-button
9
LED
flashes).
Use push-buttons 7 and 8 to set
the number of the program on display 16
.
Start up the cycle by pressing push-button 6
. When the cycle has been completed,
the appliance automatically switches to the
set storage temperature for an indefinite
time.
Press push-button 6 to set the appliance
to STOP status (relative LED switches off),
ready for a new cycle.