230 Series Auger Packer
29 OF 115
daily if necessary depending on the humidity of your environment. If excessive contamination and water
accumulate in the transparent bowl, it should be cleaned more often.
BAG SEAL REGULATOR
Place an empty bag on the filling tube. Press the Start pushbutton.
Adjust THE BAG SEAL REGULATOR PRESSURE TO 3-5 PSIG. This regulator is normally located on the
front leg left side. The gauge on the regulator only goes from 0-15 PSI. From the factory, they are
normally set very low, 1-2 PSI as to prevent damage to the rubber boot if started without a bag on the fill
spout. The seal should expand just enough to secure the valve to the fill spout. Excessive pressure will
damage/crack the valve sleeve and could damage the bag seal.
Caution: Never start the packer without a bag on the fill spout with the bag seal pressure.
Always have an empty bag on the spout. Damage could and will occur to the bag seal if over
inflated without an empty bag on the spout.
POWERED BAG CHAIR FLOW CONTROLS
Flow controls are located right on the cylinder of the bag chair. Take a 3/16blade screwdriver and
insert into the slot of the flow control. Turning clockwise will slow the motion of the cylinder down.
When adjusting the motion of the cylinder always adjust at the opposite end of the cylinder from where
the action is occurring at.
AIR PURGE STUFFING BOX PRESSURE
On the air purge stuffing box, there are controls. There is a pilot valve and a regulator. The regulated
pressure should be 0-5 PSI. If excessive air is used you will fluidize your product and you may have a
hard time getting it into the bag.