EasyManua.ls Logo

CBE 230 - Maintenance; Lubrication

CBE 230
115 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
230 Series Auger Packer
33 OF 115
APART FROM WHAT HAS BEEN SPECIFIED ABOVE, IT IS NECESSARY TO RESPECT THE REGULATIONS
APPLICABLE IN THE COUNTRY IN WHICH THE MACHINE IS OPERATED.
MAINTENANCE
WARNING: Maintenance must be performed ONLY by qualified technicians, with the
power supply disconnected.
CAUTION: Before starting operation, ensure that the temperature of the motovibrator is
not higher than 4C.
LUBRICATION
All the motovibrators are initially lubricated by the manufacturer. Motovibrators which employ ball
bearings (pre-lubricated and shielded) do not require lubrication. Models with roller bearings require
grease replacement only after 3000 hours of operation. Use KLÜBER STABURAGS NBU 8 EP grease. For
disassembling and cleaning the bearings, refer to the paragraph below. Do not mix different types of
grease even if they have similar features. An excessive amount of grease may overheat the bearings and
thus damage them.

Table of Contents

Related product manuals