230 Series Auger Packer
51 OF 115
Possible Cause: Lost Phase
Inspect fuses in control panel and replace as required.
Issue: Repeated Stalling
Possible Cause: Interruption of power-
Excessive amperage causes a trip. Inspect the motor current and adjust range as needed.
Issue: Motor runs hot
Possible Cause: Overload bad and not tripping out
Look for binding of mechanical devices, excessive belt tension, frozen or sluggish pulley, bearings.
Possible Cause: Low line voltage.
Check line voltage.
Possible Cause: Loss of one of three phases-
Inspect fuses in control panel and replace as required.
Issue: Excessive noise
Possible Cause: Insufficient belt tension-
Properly tension belt, then tighten down drive.
Possible Cause: Drive sheaves misaligned-
Reposition the drive sheaves using a straight edge across the sheave faces. Properly tension belt, then
tighten down drive.
Possible Cause: Bad bearing-
Inspect and replace as needed.
Possible Cause: Auger out of alignment
Verify auger is aligned and centered on fill spout and nozzle.
Possible Cause: Lack of lubrication-
Lubricate or Replace as required