32
cdvigroup.com
CTV900A
2-Door Controller
INSTALLATION MANUAL
BATTERY BACKUP
The controller cannot be started on battery power only. Battery backup time varies with each system. Typical
backup time is between 2 and 20 hours using standard equipment and settings. When the battery voltage drops
below 20.5V the LOW BAT LED will ash. It will restore at 23.4V. If the battery voltage drops to below 16.8V,
the controller will shut down after one minute. The LOW BAT LED will ash twice as fast (strobe) during this one
minute period.
12Vdc 7Ah rechargeable acid/lead or gel cell backup battery (UL/ULC: YUASA #NP7-12 recommended,
Europe: CDVI B7AH recommended). Ensure proper polarity. Various (means any type, from any
manufacturer that complies with the “Technical Data and securement means” and meets the “Mark of
conformity” can be used).
CTV900A
2-Door Controller
TAMPER
TAMPER
2 x Sealed
Rechargeable
GEL Type Battery
12Vdc @ 7Ah