EasyManua.ls Logo

CDVI Centaur CTV900A - Recommended Wiring; Specifications

CDVI Centaur CTV900A
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
cdvigroup.com
CTV900A
2-Door Controller
INSTALLATION MANUAL
RECOMMENDED WIRING
SPECIFICATIONS
Equipment Wire Type Size
Maximum
Length
Card reader and
Wiegand keypad
4 to 8 conductors, stranded, shielded (foil), drain
conductor. For example: Alpha 5196, 5198, 5386,
5388, Belden 9553
22AWG (0.64mm) to
18AWG (1.02mm)
150m (500ft.)
BCD keypad
12 conductors, stranded. For example: Belden
8466
18AWG (1.02mm) 150m (500ft.)
Zone input 2 conductors, copper 22AWG (0.64mm) 22AWG (0.64mm) 600m (2000ft.)
Door strike 2 conductors, solid copper 18AWG (1.02mm) 18AWG (1.02mm) 150m (500ft.)
Power Supply 3 conductors, solid copper 18AWG (1.02mm) 14AWG (1.63mm)* 8m (25ft.)
RS485 bus, Daisy
Chain (BIAS/EOL
required)
CAT 5/5e 24AWG (0.51mm) 1220m (4000ft.)
* The Minimum Size Equipment Conductors for the AC mains required are 14 AWG if made of Copper or 12
AWG if made of Aluminium or Copper-Clad Aluminium. Do not use any switch-controlled outlets to power the
system.
System Resources
Doors 2 (Add up to 6 more doors to the CTV900A using the CAA470A expansion module)
Cards Up to 10,920 (on-board)
Schedules Up to 512
Access Levels Up to 256
Buered Events Up to 2048
Holidays Up to 128
UserGroups Up to 2000
Operating Temperature 0°C to 49°C (32°F to 120°F)
Humidity 0% to 85% (non condensing)
System Autonomy Distributed Architecture
Firmware Online Upgradeable
PCB Dimensions 24.5cm (9.65”) x 20.2cm (7.95”)
Cabinet Dimensions 40 cm (15.8”) high, 32 cm (12.6”) wide, 9 cm (3.54”) deep
Inputs
Readers 2 x Wiegand Readers with Multiple Protocol Support, Magnetic Stripe ABA Track 2
Keypads 2 x Keypad with Multiple Protocol Support, including BCD format
Multi-Purpose Inputs
8 zone inputs (up to 16 using ZONE DOUBLER) with optional individual WIRE CUT &
WIRE SHORT supervision.
Tamper Normally Closed (N.C.) contact