Questions and Answers

  • G
    gpooleAug 18, 2025
    Why am I getting erratic results with my CEM SPRINT Analytical Instruments?
    • H
      Heather ConleyAug 18, 2025
      If you're getting erratic results with your CEM Analytical Instruments, several factors could be the cause. Make sure that the sample size is consistent across all tests. Ensure the sample is correctly positioned in the sample cup. Check the iTAG stirring mechanism to confirm it's functioning properly. The optics might be dirty, so try cleaning them. Also, check and calibrate the balance to rule out any balance problems.
  • S
    skiddAug 20, 2025
    What to do if my CEM Analytical Instruments show a “No Flow Detected” error?
    • A
      Amy CooperAug 20, 2025
      If you're seeing a “No Flow Detected” error on your CEM Analytical Instruments, first, ensure that water is available to the system. If water is available, check for any crimped tubing and replace it.
  • K
    Karen WilliamsAug 23, 2025
    How to fix wash station overflows in CEM SPRINT Analytical Instruments?
    • M
      Mr. Erik JohnsonAug 23, 2025
      If the wash station is overflowing on your CEM Analytical Instruments, there are a few potential causes. The wash station itself might be clogged, so try cleaning it. Also, check the tubing for any clogs and clear them if necessary. Finally, inspect the waste tubing for any crimps and reposition or replace the tubing if needed. Cleaning the wash station is also a suggested solution.
  • J
    jamespetersonAug 26, 2025
    Why is the protein result too high or low on my CEM SPRINT Analytical Instruments?
    • L
      Lisa BrewerAug 26, 2025
      If the protein result is too high or too low on your CEM Analytical Instruments, several factors could be the cause. First, verify the protein reference (Kjeldahl, etc.) and adjust it if necessary. Next, try to restandardize the iTAG. Additionally, dirty optics or a dirty homogenizer can affect results, so clean them accordingly.
  • D
    douglas36Aug 28, 2025
    What causes no iTAG added error in CEM Analytical Instruments?
    • Z
      Zachary PerkinsAug 28, 2025
      If no iTAG is being added in your CEM Analytical Instruments, check for crimped tubing and replace it if necessary. Also, make sure that the cap on the iTAG bottle is not tightened; loosen it if it is.
  • D
    Dylan BennettAug 30, 2025
    How to stop water from splashing in the wash station of CEM SPRINT?
    • K
      Kelly AlexanderAug 31, 2025
      If water is splashing in the wash station of your CEM Analytical Instruments, the pressure might not be properly set. Adjust the pressure to the correct range, which is typically between 10 and 15 psi.
  • V
    Vincent GentrySep 2, 2025
    Why is iTAG splattering in the sample cup of my CEM SPRINT Analytical Instruments?
    • D
      deborah88Sep 2, 2025
      If the iTAG is splattering in the sample cup of your CEM Analytical Instruments, it could be due to a dirty homogenizer. Try cleaning the homogenizer. Alternatively, the homogenizer bearing might need replacement, so consider replacing it.
  • C
    Carl NavarroSep 4, 2025
    How to resolve unit-to-unit variability in CEM SPRINT Analytical Instruments results?
    • C
      Carol PerezSep 4, 2025
      If you're experiencing unit-to-unit variability in results with your CEM Analytical Instruments, it could be due to an improper iTAG reference. Try re-running the Gold Standard.
  • J
    Jasmine AndradeSep 7, 2025
    What to do if the pressure is rising in CEM SPRINT Analytical Instruments?
    • D
      dylankaufmanSep 7, 2025
      If you notice a rising pressure in your CEM Analytical Instruments, there may be debris in the regulator. Open, flush (clockwise), and then reset the regulator.
  • R
    Robert JacksonSep 9, 2025
    Why does the water in my CEM SPRINT system "steam"?
    • L
      laliSep 9, 2025
      If the water in your CEM Analytical Instruments system "steams", it's likely due to improper heater calibration. You should calibrate the heater properly.

Summary

Operating Precautions

Warnings and Cautions

Explains the meaning of warning and caution notes used in the manual for safety and operational guidance.

Overview

SPRINT Operation

Details the step-by-step procedure for performing an analysis using the SPRINT® instrument.

System Setup

External Balance Setup

Guides the user through connecting and configuring an external balance with the Sprint instrument.

Solution Preparation

Details how to prepare the necessary iTAG and cleaning solutions for the instrument.

Homogenizer Installation

Provides instructions on how to properly install the homogenizer assembly into the instrument.

Sprint Keypad

Instrument Setup

User Management

Sample ID Settings

Balance Settings

Describes how to configure the external balance type and its communication settings.

SPRINTPAK Setup

SPRINTPAK Restandardization

Instrument Operation

Load Method

Describes how to select and load a pre-defined analysis method.

Edit Method

Guides on how to modify existing analysis methods.

Create Method

Method Parameters

Describes how to set method name, bias, and result precision.

Sample Details

Details how to set sample weight and protein parameters.

Run Details

Explains how to configure homogenization, filter height, delay, and settling times.

References

Describes how to add and manage calibration reference points for a method.

Stop Method

Print

Maintenance

Guides on performing routine maintenance tasks like cleaning and system checks.

Maintenance, Troubleshooting and Service

Routine Maintenance and Cleaning

Details daily, weekly, monthly, and quarterly maintenance tasks.

Preparation for Shipment

Spill Removal

Troubleshooting

CEM SPRINT Specifications

General IconGeneral
BrandCEM
ModelSPRINT
CategoryAnalytical Instruments
LanguageEnglish