TM70 Handheld Wireless Remote Control
U003.6.0-TM70_HH_SYS-R
Figure 8. TM70 Transmitter Details
Table 4 below shows the receiver LEDs upon receiving a signal from the transmitter.
Table 4. Receiver LEDs Upon Receiving a Transmitter Signal
Defects have not been detected on the board
Data received has a correct format
Receiver has recognized the transmitter ID code
3. Press any of the transmitter’s movement pushbuttons. Its corresponding
relay is energized. In case of an active movement, the safety relay
K1/SAFETY is also energized.
4. Check to make sure all the other movements work as described in Step 3.
5. Turn off the transmitter using the STOP Button, and make sure that
when doing so the relays are not energized and the DATA, ID, and
SIGNAL LEDs go out. They should behave exactly as when in the
SCANNING mode.
6. Reconnect the power supply to the motors, move to a safe position, and
check to see if all the movement pushbuttons and the STOP Button
correctly function.
Crane ID Label
Option: LCD Display