4.2 Power and Energy
4.2.1 Basic Measurements
The PMC-340 provides the following basic measurements which can be retrieved via the Front panel
or communication:
Parameter
Phase A
Phase B
Phase C
Total
Average
Uln
-
Ull
-
Current
-
kW
-
kvar
-
kVA
-
Power Factor
-
Frequency
-
-
-
-
Table 4-2 Basic Measurements
4.2.2 Energy Measurements
The PMC-340 provides Energy measurements for active energy (kWh), reactive energy (kvarh) and
apparent energy (kVAh) with a resolution of 0.01 kxh and maximum value of 10,000,000.00. When
the maximum value is reached, the energy registers will automatically roll over to zero. The energy
can be reset manually through the front panel or communication.
The PMC-340 provides the following energy measurements:
3-Phase Energy
kWh Import/Export/Net/Total
kWh Import/Export of Tariff 1/2/3/4
kvarh Import/Export/Net/Total
kvarh Import/Export of Tariff 1/2/3/4
kvarh of Q1/Q2/Q3/Q4
kVAh Total
Per-Phase Energy
(Phase A/B/C):
kWh Import/Export/Net/Total
kWh Import/Export of Tariff 1/2/3/4
kvarh Import/Export/Net/Total
kvarh Import/Export of Tariff 1/2/3/4
kvarh of Q1/Q2/Q3/Q4
kVAh
Table 4-3 Energy Measurement
4.2.3 Demand Measurements
Demand is defined as the average power consumption over a fixed interval (usually 15 minutes)
based on the sliding window method. The PMC-340 provides the following Demand and Peak
Demand measurements:
Demands
Ia, Ib, Ic
kW Total, kvar Total, kVA Total
Peak Demands
Ia, Ib, Ic
kW Total, kvar Total, kVA Total
kW Total, kvar Total and kVA Total for each Tariff
Table 4-4 Demand Measurement
The PMC-340 provides the following Demand setup parameters:
Setup Parameter
Definition
Options
Demand Period
1 to 60 minutes. For example, if the # of Sliding Windows
is set as 1 and the Demand Period is 15, the demand cycle
will be 1×15=15min.
1 to 60 minutes
Default=15
# of Sliding
Windows
Number of Sliding Windows.
1 to 15
Default=1

Table of Contents

Other manuals for CET PMC-340

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CET PMC-340 and is the answer not in the manual?

CET PMC-340 Specifications

General IconGeneral
BrandCET
ModelPMC-340
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals