EasyManuals Logo

CET PMC-340 User Manual

CET PMC-340
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
CET Inc.
54
121
kWh Import of T2
INT32
301
Ib TDD
Float
122
kWh Export of T2
INT32
302
Ic TDD
Float
123
kvarh Import of T2
INT32
303
Ia TDD Odd
Float
124
kvarh Export of T2
INT32
304
Ib TDD Odd
Float
125
kVAh of T2
INT32
305
Ic TDD Odd
Float
126
kWh Import of T3
INT32
306
Ia TDD Even
Float
127
kWh Export of T3
INT32
307
Ib TDD Even
Float
128
kvarh Import of T3
INT32
308
Ic TDD Even
Float
129
kvarh Export of T3
INT32
309
Ia K-factor
Float
130
kVAh of T3
INT32
310
Ib K-factor
Float
131
kWh Import of T4
INT32
311
Ic K-factor
Float
132
kWh Export of T4
INT32
312
Ia C-factor
Float
133
kvarh Import of T4
INT32
313
Ib C-factor
Float
134
kvarh Export of T4
INT32
314
Ic C-factor
Float
135
kVAh of T4
INT32
315
Voltage Unbalance
Float
Phase A (L1) Energy Measurements
316
Current Unbalance
316
136
kWh Import
INT32
317
Uan/Uab THD
Float
137
kWh Export
INT32
318
Ubn/Ubc THD
Float
138
kWh Net
INT32
319
Ucn/Uca THD
Float
139
kWh Total
INT32
320
Uan/Uab TOHD
Float
140
kvarh Import
INT32
321
Ubn/Ubc TOHD
Float
141
kvarh Export
INT32
322
Ucn/Uca TOHD
Float
142
kvarh Net
INT32
323
Uan/Uab TEHD
Float
143
kvarh Total
INT32
324
Ubn/Ubc TEHD
Float
144
kVAh
INT32
325
Ucn/Uca TEHD
Float
145
kvarh Q1
INT32
326
Uan/Uab HD02
Float
146
kvarh Q2
INT32
327
Ubn/Ubc HD02
Float
147
kvarh Q3
INT32
328
Ucn/Uca HD02
Float
148
kvarh Q4
INT32
Float
149
kWh Import of T1
INT32
413
Ia HD31
Float
150
kWh Export of T1
INT32
414
Ib HD31
Float
151
kvarh Import of T1
INT32
415
Ic HD31
Float
152
kvarh Export of T1
INT32
Demand
153
kVAh of T1
INT32
600
Ia Present Demand
Float
154
kWh Import of T2
INT32
601
Ib Present Demand
Float
155
kWh Export of T2
INT32
602
Ic Present Demand
Float
156
kvarh Import of T2
INT32
603
kW Present Demand
Float
157
kvarh Export of T2
INT32
604
kvar Present Demand
Float
158
kVAh of T2
INT32
605
kVA Present Demand
Float
159
kWh Import of T3
INT32
606
Ia Max. Demand
Float
160
kWh Export of T3
INT32
607
Ib Max. Demand
Float
161
kvarh Import of T3
INT32
608
Ic Max. Demand
Float
162
kvarh Export of T3
INT32
609
kW Max. Demand
Float
163
kVAh of T3
INT32
610
kvar Max. Demand
Float
164
kWh Import of T4
INT32
611
kVA Max. Demand
Float
165
kWh Export of T4
INT32
612
T1 kW Max. Demand
Float
166
kvarh Import of T4
INT32
613
T1 kvar Max. Demand
Float
167
kvarh Export of T4
INT32
614
T1 kVA Max. Demand
Float
168
kVAh of T4
INT32
615
T2 kW Max. Demand
Float
Phase B (L2) Energy Measurements
616
T2 kVA Max. Demand
408
169
kWh Import
INT32
617
T2 kVA Max. Demand
Float
170
kWh Export
INT32
618
T3 kW Max. Demand
Float
171
kWh Net
INT32
619
T3 kvar Max. Demand
Float
172
kWh Total
INT32
620
T3 kVA Max. Demand
Float
173
kvarh Import
INT32
621
T4 kW Max. Demand
Float
174
kvarh Export
INT32
622
T4 kvar Max. Demand
Float
175
kvarh Net
INT32
623
T4 kVA Max. Demand
Float

Table of Contents

Other manuals for CET PMC-340

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CET PMC-340 and is the answer not in the manual?

CET PMC-340 Specifications

General IconGeneral
BrandCET
ModelPMC-340
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals