R3250Hz Universal Outdoor Series Technical Manual
151
GD Chigo Heating & Ventilation Equipment Co., Ltd.
Pressing this key in the other modes, the wind speed switches by "automatic wind speed, high
speed, middle speed, low speed, automatic wind speed " circularly.
8
FAN +
When the first power on, the remote controller is set to the automatic wind speed by default. In
dehumidification mode, the wind speed is fixed to low wind and is not adjustable. By pressing the
wind speed key, there is no response to the remote controller.
Pressing this key in the other modes, the wind speed switches by "automatic wind speed, low
speed, middle speed, high speed, automatic wind speed " circularly.
9
Timer
Under the shutdown state, press this key to set the opening time, range from 1 hour to 24 hour.
Under the boot state, press this key to set the shutdown time, range from 1 hour to 24 hour.
The timing time is according to the cycle of "1h, 2h, ……, 23h, 24h, cancel, 1h".
Exit timing adjustment after 3 seconds without key pressing.
10
TURBO
Extension code remote controller has the effect. The remote controller is no TURBO by default,
and the TURBO key will not work in automatic mode, dehumidification mode and fan mode.
Pressing this key in the cooling or heating mode, the TURBO mode switches between opening and
closing. When in the TURBO mode, it does not display the wind speed. Switching mode or entering
sleep function will close TURBO mode.
If the air conditioner has four gear wind speeds, the TURBO icon will light up and the fan will run in
the fourth gear wind speed by pressing this key.
11
ECON
The remote controller is no ECON by default, and the ECON key will not work in automatic mode,
dehumidification mode and fan mode.
Pressing this key in the cooling or heating mode, the ECON mode switches between opening and
closing. When in the ECON mode, the setting temperature is set to 26 (77
) and other settings
are unchanged. If closing ECON mode, the remote controller will recover to the setting before
opening ECON mode. Switching mode will close ECON mode.
12
Sleep
Pressing this key in the modes except of the fan mode, the sleep function switches between
opening and closing. Switching mode will cancel sleep function.