R3250Hz Universal Outdoor Series Technical Manual
GD Chigo Heating & Ventilation Equipment Co., Ltd.
12. Trouble shooting
12.1 Fault codes table
Table 1: Indoor unit (digital display)
When unit is standby after first time power on, running light flash slowly, after operation, all the lights off
when the unit is off or standby.
When unit is running, running light flashes, digital tube shows setting temperature in cooling and heating
mode, digital tube shows indoor temperature in fan only mode; defrost light turns on when defrosting, timer
light turns on when in timer mode.
E1
Communication error between
outdoor unit and indoor unit
F1
(reserve)
E2
Indoor room temperature (T1)
F2
(reserve)
E3
Indoor coil middle temperature (T2)
sensor error
F3
Outdoor unit current error cannot
recover
Display P3 error for 3 times within
E4
Indoor coil outlet temperature
F4
Outdoor temperature (T4) sensor
E6
Zero speed protection
F6
Outdoor unit condenser outlet
E7
EERPOM error
F7
Secondary side current
E8
Indoor fan motor speed lose
F8
Heat T2 temp. protection
E9
Wired controller communication
F9
Outdoor unit voltage error
Table 2: Indoor unit (LED display)
Error description
Display
Indoor unit waiting for address assignment
LED timer and running flash together
(reserve)
LED timer, running, protection, defrost
Communication error between outdoor unit and indoor unit
Fan motor stall protection
Indoor unit temperature sensor error
LED protection flash slowly