EasyManua.ls Logo

Chore-Time FLEX-AUGER 108 - Auger Tube Installation

Default Icon
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Model 108 FLEX-AUGER Installation Manual
( 15 )
Chart for minimum distances ("X") from building to center of bin using the various entrance heights ("H"), upper boots and
elevations listed below.
System Model Entrance Height 30 Degree Upper Bin Boot (part no. 4347) Straight-Out Upper Bin Boot (part no. 6093)
"H" 30 Degree 45 Degree 30 Degree 45 Degree
5’ (1.5 m) 12.5’ (3.8 m) 11.5’ (3.5 m) 15’ (4.6 m) 14’ (4.3 m)
6’ (1.8 m) 14’ (4.3 m) 12.5’ (3.8 m) 16.5’ (5 m) 15’ (4.6 m)
7’ (2.1 m) 16’ (4.9 m) 13.5’ (4.1 m) 18.5’ (5.6 m) 16’ (4.9 m)
8’ (2.4 m) 17.5’ (5.3 m) 14.5’ (4.4 m) 20’ (6.1 m) 17’ (5.2 m)
9’ (2.7 m) 19.5’ (5.9 m) 15.5’ (4.7 m) 22’ (6.7 m) 18’ (5.5 m)
10’ (3 m) 21’ (6.4 m) 16.5’ (5 m) 23.5’ (7.2 m) 19’ (5.8 m)
11’ (3.4 m) 23’ (7 m) 17.5’ (5.3 m) 25.5’ (7.8 m) 20’ (6.1 m)
12’ (3.7 m) 24.5’ (7.5 m) 18.5’ (5.6 m) 27’ (8.2 m) 21’ (6.4 m)
13’ (4 m) 26.5’ (8.1 m) 19.5’ (5.9 m) 29’ (8.8 m) 22’ (6.7 m)
14’ (4.3 m) 28’ (8.5 m) 20.5’ (6.2 m) 30.5’ (9.3 m) 23’ (7 m)
15’ (4.6 m) 29.5’ (9 m) 21.5’ (6.5 m) 32.5’ (9.9 m) 24’ (7.3 m)
16’ (4.9 m) 31.5’ (9.6 m) 22.5’ (6.8 m) 34’ (10.4 m) 25’ (7.6 m)
17’ (5.2 m) 33’ (10 m) 23.5’ (7.2 m) 35.5’ (10.8 m) 26’ (7.9 m)
18’ (5.5 m) 35’ (10.7 m) 24.5’ (7.5 m) 37.5’ (11.4 m) 27’ (8.2 m)
19’ (5.8 m) 36.5’ (11.1 m) 25.5’ (7.8 m) 39’ (11.9 m) 28’ (8.5 m)
20’ (6.1 m) 38.5’ (11.7 m) 26.5’ (8.1 m) 41’ (12.5 m) 29’ (8.8 m)
5’ (1.5 m) 11’ (3.4 m) 9.5’ (2.9 m) 11’ (3.4 m) 9.5’ (2.9 m)
6’ (1.8 m) 13’ (4 m) 10.5’ (3.2 m) 13’ (4 m) 10.5’ (3.2 m)
7’ (2.1 m) 14.5’ (4.4 m) 11.5 (3.5 m) 14.5’ (4.4 m) 11.5’ (3.5 m)
8’ (2.4 m) 16’ (4.9 m) 12.5’ (3.8 m) 16’ (4.9 m) 12.5’ (3.8 m
9’ (2.7 m) 18’ (5.5 m) 13.5’ (4.1 m) 18’ (5.5 m) 13.5’ (4.1 m)
10’ (3 m) 19.5’ (5.9 m) 14.5’ (4.4 m) 19.5’ (5.9 m) 14.5’ (4.4 m)
11’ (3.4 m) 21.5’ (6.5 m) 15.5’ (4.7 m) 21.5’ (6.5 m) 15.5’ (4.7 m)
12’ (3.7 m) 23’ (7 m) 16.5’ (5 m) 23’ (7 m) 16.5’ (5 m)
13’ (4 m) 25’ (7.6 m) 17.5’ (5.3 m) 25’ (7.6 m) 17.5’ (5.3 m)
14’ (4.3 m) 26.5’ (8.1 m) 18.5’ (5.6 m) 26.5’ (8.1 m) 18.5’ (5.6 m)
15’ (4.6 m) 28.5’ (8.7 m) 19.5’ (5.9 m) 28.5’ (8.7 m) 19.5’ (5.9 m)
16’ (4.9 m) 30’ (9.1 m) 20.5’ (6.2 m) 30’ (9.1 m) 20.5’ (6.2 m)
17’ (5.2 m) 32’ (9.8 m) 21.5’ (6.5 m) 32’ (9.8 m) 21.5’ (6.5 m)
18’ (5.5 m) 33.5’ (10.2 m) 22.5’ (6.8 m) 33.5’ (10.2 m) 22.5’ (6.8 m)
19’ (5.8 m) 35.5’ (10.8 m) 23.5’ (7.1 m) 35.5’ (10.8 m) 23.5’ (7.2 m)
20’ (6.1 m) 37’ (11.3 m) 24.5’ (7.4 m) 37’ (11.3 m) 24.5’ (7.5 m)
Use this diagram and chart to determine proper
feed bin placement when using screener.
"X" = distance from center of bin to where fill system
enters the building.
"H" = height from top of bin pad to where fill system
enters the building.
Degree of elevation = Angle at which the system is
installed (from horizontal).
System shown with screener boot installed in-line;
system may also be installed with the screener boot
rotated 90 degrees.
Model 108 using
screener.
Screener Boot is
in-line with system.
Model 108 using
screener.
Screener Boot is
rotated 90 degrees
to system.
Model 108 FLEX-AUGER Systems Bin Placement Chart
(with In-Line or Rotated Screeners)