Model 108 FLEX-AUGER Installation Manual
Operating Recommendations for the
Model 108 FLEX-AUGER
1. During initial start-up, the boot slide should be only partially open
to prevent the full length of auger from being charged with feed.
After that, the boot slide must be fully open for delivery system
operation.
2. Do not permit the FLEX-AUGER system to operate empty. Use a
time clock or Auger Timer with the system whenever possible.
This reduces short cycling by operating on a preset schedule in-
stead of on demand. It also prevents excessive running of the
system if the bin becomes empty. If the optional boot switch is
used, the fill system will shut down when the bin becomes empty.
3. Program the time clock to fill feeders often so the FLEX-AUGER
System does not have to run a long period of time to get feeders
filled. Poultry feeders supplied by the FLEX-AUGER System
should be operated by a time clock so feeders start at the same
time. This gives the FLEX-AUGER System a better chance to
keep up with them.
Note: The hopper level control must be positioned low in the last
feeder hopper.
4. The red light on the control unit will light if feed has packed in-
side. If this happens, remove feed from the drop tube and tap the
side of the power unit to clear the safety switch. Keep the hopper
level control in adjustment and positioned straight up and down
so the paddle swings freely. The safety switch does not take the
place of the hopper level control.
5. If the FLEX-AUGER System must be used to convey high-mois-
ture feed, empty the auger line completely after each running to
prevent the feed from setting up in the tubes.
6. The Restrictor in the boot regulates the amount of feed flowing
into the auger. Start a new system with the Restrictor installed as
shipped--full length and flush with the front of the boot. Allow the
system to polish out before adjusting the feed flow. Maximum re-
striction for the boots results when the restrictor is in this posi-
tion. If more feed flow is desirable, the restrictor may be
shortened. Refer to the section “Restrictor Adjustment” on page
34.
7. When operating the Straight-Through Tandem System, open the
slide on only one bin at a time!
8. Model 108 High-Moisture Corn Appplications only:
Chore-Time recommends purging the system after the last feed-
ing each day. Do not allow feed to set in the tubes for more than
24 hours.
Additionally, do not allow the charged system to set idle in freez-
ing conditions for extended periods of time.