Programmable AC Source 6430/6420/6415 User‘s Manual
:RANGe 150|300 Sets the output voltage range
:AUTO <Boolean> Enables/Disables AUTO output voltage range mode
STATus
PRESet Presets the PTR, NTR and Enable Registers of
Questionable and Operation status
:OPERation
[:EVENt]? Returns the content of the Event Register
:CONDition? Returns the content of the Condition Register
:ENABle <NRf> Sets the Enable Register
:QUEStionable
[:EVENt]? Returns the content of the Event Register
:CONDition? Returns the content of the Condition Register
:ENABle <NRf> Sets the Enable Register
:NTRansition <NRf> Sets the negative transition filter
:PTRansition <NRf> Sets the positive transition filter
SYSTem
:ERRor? Returns the error message
:LOCal Goes to local mode (RS-232C only)
:REMote Goes to remote mode (RS-232C only)
:RWLock Goes to remote with lockout mode (RS-232C only)
*CLS Clears status
*ESE <NRf> Sets the Standard Event Status Enable Register
*ESR? Returns the Standard Event Status Register
*IDN? Returns the device identification
*OPC Generates operation complete message when
operation completes
6-8