EasyManuals Logo

Chroma 6430 User Manual

Chroma 6430
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #51 background imageLoading...
Page #51 background image
Remote Operation
*OPC? Returns ā€œ1ā€ when operation completes
*RST Reset
*SRE <NRf> Sets Service Request Enable Register
*STB? Returns Status Byte Register
*TST? Performs self-test, then returns result
*WAI Wait-to-continue
6.6.2 Command Dictionary
MEASure:CURRent:AC?
FETCh:CURRent:AC?
Description: These queries return the output AC rms current. It is noted that there are two
kinds of commands to get measurement data. MEASure commands make a
new measurement and return measurement data. FETCh commands return
measured data taken by previous MEASure command. Note that once a new
measurement is made, all new measurement data (V, F, I, P, PF, CF) may be
returned by FETCh commands.
Query Syntax: MEASure[:SCALar]:CURRent:AC?
FETCh[:SCALar]:CURRent:AC?
Parameters: None
Return Parameters: <NR2>
Query Example: MEAS:CURR:AC? returns the output AC rms current.
MEASure:CURRent:CREStfactor?
FETCh:CURRent:CREStfactor?
Description: These queries return the output current crest factor.
Query Syntax: MEASure[:SCALar]:CURRent:CREStfactor?
FETCh:[SCALar]:CURRent:CREStfactor?
Parameters: None
Return Parameters: <NR2>
Query Example: MEAS:CURR:CRES? returns the output current crest factor.
6-9