Programmable AC Source 6430/6420/6415 User‘s Manual
MEASure:FREQuency?
FETCh:FREQuency?
Description: These queries return the output frequency.
Query Syntax: MEASure[:SCALar]:FREQuency?
FETCh[:SCALar]:FREQuency?
Parameters: None
Return Parameters: <NR2>
Query Example: MEAS:FREQ? returns the output frequency.
MEASure:POWer:AC?
FETCh:POWer:AC?
Description: These queries return the output real power.
Query Syntax: MEASure[:SCALar]:POWer:AC[:REAL]?
FETCh[:SCALar]:POWer:AC[:REAL]?
Parameters: None
Return Parameters: <NR2>
Query Example: MEAS:POW:AC? returns the output real power.
MEASure:POWer:AC:PFACtor?
FETCh:POWer:AC:PFACtor?
Description: These queries return the output power factor.
Query Syntax: MEASure[:SCALar]:POWer:AC:PFACtor?
FETCh[:SCALar]:POWer:AC:PFACtor?
Parameters: None
Return Parameters: <NR2>
Query Example: MEAS:POW:AC:PFAC? returns the output power factor.
MEASure:VOLTage:AC?
FETCh:VOLTage:AC?
Description: These queries return the output AC rms voltage.
Query Syntax: MEASure[:SCALar]:VOLTage:AC?
FETCh[:SCALar]:VOLTage:AC?
Parameters: None
Return Parameters: <NR2>
6-10