INSTALLATION MANUAL PRORAPID |
The operating mode
‚Manual‘ may only be used
by specialists for brief
function tests, e.g. during
commissioning! Function in
manual mode: The relays
and thus the connected
consumers are switched on
and o by pressing a key,
with no regard to
the current temperatures
and set parameters. At
the same time, the current
measurement values of
temperature sensors are
also shown in the display
for the purposes of function
control.
O
If the operating mode
“o” is enabled, all control
functions are turned o. The
measured temperatures are
displayed for the overview.
3. Settings
Minimum storage temperature
If this value falls below this value at the
associated storage sensor outside the
enable times for heating, the heating is
nevertheless started.
Storage target temperature
Storage target temperature
If this value falls below this value at the
associated storage sensor during the
enabling times for heating, the heating is
started. The storage target temperature is
composed of the set value + the switch-o
hysteresis.
Switch O hysteresis
Switch-o hysteresis for storage heating
The storage target temperature is calculated
from Tmin or Tset storage at the given
operating time plus the hysteresis set here. If
By no means does the
controller replace the safety
appliances on site!
Exit settings
4.2 Tset storage
4.1 Tmin storage
40ºC
Info
58ºC