93
Update
You may configure in which format the collected data will be output to the host computer.
Barcode read by the scanner will be processed in the following sequence –
1) Perform character substitution on the data scanned.
2) Add
Code ID and Length Code to the front of the data:[Code ID][Length Code][Data]
3) Process the whole data in step 2 with user formats. Data is now divided into fields by
user specified rules. Refer to
Chapter 5 Applying Formats for Data Editing.
4) Add
Prefix Code and Suffix Code before transmission:[Prefix Code][Processed
Data][Suffix Code]
IN THIS CHAPTER
4.1 Letter Case............................................................... 93
4.2 Character Substitution................................................ 94
4.3 Prefix/Suffix Code.....................................................102
4.4 Code ID...................................................................103
4.5 Length Code ............................................................107
4.6 Multi-Barcode Editor..................................................111
4.7 Removal of Special Character .....................................114
4.1 LETTER CASE
By default, the alphabets transmission is case-sensitive, meaning that the alphabets will
be transmitted according to their original case. Ignoring the original letter case, select
[Upper Case] to output data in upper case only; otherwise, select [Lower Case] to output
data in lower case only.
*Normal
Upper Case
Lower Case
Chapter 4