EasyManua.ls Logo

Cirrus SR22T - Low Alternator 2 Output

Cirrus SR22T
506 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3A-14 P/N 13772-005
Section 3A Cirrus Design
Abnormal Procedures SR22T
Low Alternator 2 Output
ALT 2 Caution (Failure)
1. ALT 2 Circuit Breaker ..............................................CHECK & SET
2. ALT 2 Master Switch ...........................................................CYCLE
If alternator does not reset (low A2 Current and M2 voltage less
than M1 voltage):
3. ALT 2 Master Switch ................................................................OFF
4. Continue Flight, avoiding IMC or night flight as able (reduced
power redundancy).
Amplification
Alternator 2 output is low, indicative of alternator failure; isolated Alt 2
failure will not typically be associated with any other unusual
indications, cautions or warnings (Alt 1 will pick up all loads).
ALT 2
Original Issue

Table of Contents

Other manuals for Cirrus SR22T

Related product manuals