EasyManuals Logo

Cirrus SR22T User Manual

Cirrus SR22T
506 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #88 background imageLoading...
Page #88 background image
3-32 P/N 13772-005
Section 3 Cirrus Design
Emergency Procedures SR22T
Electrical System Emergencies
High Voltage on Main Bus 1
M BUS 1 Warning
1. ALT 1 Master Switch ...........................................................CYCLE
2. M Bus 1 Voltage (M1)......................................................... CHECK
If M Bus 1 Voltage is greater than 32 volts.
3. ALT 1 Master Switch ................................................................OFF
4. Perform ALT 1 Caution (Failure) Checklist (do not reset alternator)
Amplification
Main Bus 1 Voltage is excessive, indicates an alternator 1 voltage
regulator failure; will typically be associated with abnormally high
voltage indications on M1, M2 and ESS busses, may also be
associated with M Bus 2 or ESS BUS Warning message.
M BUS 1
Original Issue

Table of Contents

Other manuals for Cirrus SR22T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cirrus SR22T and is the answer not in the manual?

Cirrus SR22T Specifications

General IconGeneral
ManufacturerCirrus Aircraft
EngineContinental TSIO-550-K
Horsepower315 hp
Max Takeoff Weight3, 600 lbs
Service Ceiling25, 000 ft
Cabin Width49 in
Cabin Height50 in
Seating Capacity4
AvionicsCirrus Perspective+ by Garmin
CategorySingle-engine piston aircraft
PropellerHartzell 3-blade composite
Wingspan38 ft 4 in
Length26 ft
Height8 ft 11 in
Maximum Cruise Speed213 KTAS
Fuel Capacity92 gallons
Stall Speed64 knots
Safety FeaturesCirrus Airframe Parachute System (CAPS)
Cruise Speed183 knots