8-24 P/N 13772-005
Section 8 Cirrus Design
Handling and Servicing SR22T
Battery #2 is a maintenance free, rechargeable, sealed, lead acid
batter. Mounted in the empennage just aft of bulkhead 222, there is no
need to check the specific gravity of the electrolyte or add water to
these batteries during their service life. Refer to the AMM for Overhaul
and Replacement Schedule.
The external power receptacle is located on the left side of the
fuselage just aft of the firewall. Refer to the AMM for battery servicing
procedures.
Oxygen System Servicing
• Caution •
To preclude the possi bility of fire by spontaneous combustion,
oil, grease, paint, hydraulic fluid, nd other flammable material
should be kept away from oxygen equipment.
Service the oxygen system per the appropriate revision of the Precise
Flight Instructions for Continued Airworthiness for the Cirrus SR20/
SR22 Built-In Oxygen System, STC number SA01708SE, document
number 102NPMAN0003.
Original Issue

Table of Contents

Other manuals for Cirrus SR22T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cirrus SR22T and is the answer not in the manual?

Cirrus SR22T Specifications

General IconGeneral
ManufacturerCirrus Aircraft
EngineContinental TSIO-550-K
Horsepower315 hp
Max Takeoff Weight3, 600 lbs
Service Ceiling25, 000 ft
Cabin Width49 in
Cabin Height50 in
Seating Capacity4
AvionicsCirrus Perspective+ by Garmin
CategorySingle-engine piston aircraft
PropellerHartzell 3-blade composite
Wingspan38 ft 4 in
Length26 ft
Height8 ft 11 in
Maximum Cruise Speed213 KTAS
Fuel Capacity92 gallons
Stall Speed64 knots
Safety FeaturesCirrus Airframe Parachute System (CAPS)
Cruise Speed183 knots

Related product manuals