Cirrus Design Section 7
SR22T Systems Description
P/N 13772-005 7-51P/N 13772-005 7-51
Main Distribution Bus 1 or Main Distribution Bus 2 in the MCU. In the
case of both alternators failing, BAT 1 is connected directly to the
Essential Distribution Bus in the MCU and will power ESS BUS 1 and
ESS BUS 2. In the event of both alternators and BAT 1 failing, BAT 2 is
connected directly to ESS BUS 1.
Main Buses
The circuit breaker panel MAIN BUS 1 and MAIN BUS 2 are powered
by ALT 2 from the MCU Main Distribution Bus 2 and - in the event of
ALT 2 failure - by ALT 1 and BAT 1 from the Main Distribution Bus 2 via
the diode interconnecting the MCU distribution buses through 30-amp
fuses inside the MCU.
The 10-amp AVIONICS circuit breaker on MAIN BUS 1, controlled
through the AVIONICS master switch on the bolster switch panel,
powers all loads on the AVIONICS BUS.
The circuit breaker panel MAIN BUS 3 is powered by ALT 1 and BAT 1
from the MCU Main Distribution Bus 1 through a 30-amp fuse inside
the MCU. In the event of ALT 1 failure, BAT 1 will power MAIN BUS 3.
ALT 2 is prevented from powering MAIN BUS 3 by the isolation diode
interconnecting the MCU distribution buses 1 and 2.
Non-Essential Buses
The circuit breaker panel NON ESS BUS is powered by ALT 2 from the
MCU Main Distribution Bus 2 and - in the event of ALT 2 failure - by
ALT 1 and BAT 1 from the Main Distribution Bus 2 via the diode
interconnecting the MCU distribution buses through 30-amp fuses
inside the MCU. The Avionics Non-Essential Bus is powered through
the 10-amp AVIONICS circuit breaker on MAIN BUS 1 and is
discussed above.
The circuit breaker panel A/C BUS 1 and A/C BUS 2, is powered by
ALT 1 and BAT 1 from the MCU Main Distribution Bus 1 through a 30-
amp fuse inside the MCU. In the event of ALT 1 failure, BAT 1 will
power A/C BUS 1 and A/C BUS 2. ALT 2 is prevented from powering
A/C BUS 1 and A/C BUS 2 by the isolation diode interconnecting the
MCU distribution buses 1 and 2.
Original Issue

Table of Contents

Other manuals for Cirrus SR22T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cirrus SR22T and is the answer not in the manual?

Cirrus SR22T Specifications

General IconGeneral
ManufacturerCirrus Aircraft
EngineContinental TSIO-550-K
Horsepower315 hp
Max Takeoff Weight3, 600 lbs
Service Ceiling25, 000 ft
Cabin Width49 in
Cabin Height50 in
Seating Capacity4
AvionicsCirrus Perspective+ by Garmin
CategorySingle-engine piston aircraft
PropellerHartzell 3-blade composite
Wingspan38 ft 4 in
Length26 ft
Height8 ft 11 in
Maximum Cruise Speed213 KTAS
Fuel Capacity92 gallons
Stall Speed64 knots
Safety FeaturesCirrus Airframe Parachute System (CAPS)
Cruise Speed183 knots

Related product manuals