2-88
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
OL-9772-05
Chapter 2 Message and Recovery Procedures
PM Messages
Error Message PM-4-INVALID_HOST_ACCESS_ENTRY: Invalid Host access entry type ([dec])
is received.
Explanation An invalid host access entry type was received. The host access entry should be a
configured or a dynamic type. [dec] is the entry type that is received.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7.
Error Message PM-4-LIMITS: The number of vlan-port instances on [chars] exceeded the
recommended limit of [dec].
Explanation The total number of individual VLAN ports on the module or the switch has exceeded
the recommended limit. VLANs can be counted more than once. If VLAN 1 is carried on ten
interfaces, it counts as ten VLAN ports. On some platforms, bundling is also ignored for purposes
of this count. If eight interfaces on the same module are in one bundle, and the port channel is
carrying VLAN 1, it counts as eight VLAN ports. [chars] is the module name (for example, switch
or the module number), and [dec] is the recommended limit.
Recommended Action Reduce the number of trunks and VLANs configured in the module or switch
as recommended in [dec]. Enter the show interfaces trunk privileged EXEC command to see the
total number of trunks and VLANs.
Error Message PM-4-NO_SUBBLOCK: No PM subblock found for [chars].
Explanation The port manager did not find the subblock for this interface. [chars] is the interface
name.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7.
Error Message PM-4-PORT_BOUNCED: Port [chars] was bounced by [chars].
Explanation During a change-over when the port was in the link-down state, the port manager
restarted the port. A port can be restarted only when the port data structures are not consistent in the
active and standby supervisors. Active ports in the link-down state return to the link-up state when
the port is restarted. The first [chars] is the port number, and the second [chars] is the re-activation
event.
Recommended Action No action is required.

Table of Contents

Other manuals for Cisco Catalyst 3750-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3750-X and is the answer not in the manual?

Cisco Catalyst 3750-X Specifications

General IconGeneral
Switching Capacity160 Gbps
Stacking Bandwidth64 Gbps
Max Stacking Units9
Layer SupportLayer 2 and Layer 3
Form FactorRack-mountable
DRAM256 MB
Flash Memory64 MB
ModelCisco Catalyst 3750-X Series
Ports24 or 48 10/100/1000 Ethernet ports
Uplink Interfaces4 SFP or 2 SFP+
FeaturesStackWise Plus, EnergyWise
ImageIP Base or IP Services
Operating Temperature0 to 40°C
Operating Humidity10 to 85% noncondensing

Related product manuals