Chapter 2 Message and Recovery Procedures
PLATFORM_ENV Messages
Error Message PLATFORM_ENV-1-RPS_SYS_POWER_GOOD: [chars].
Explanation The RPS 2300 system power state changed to good. [chars] is the error message.
Recommended Action No action is required.
Error Message PLATFORM_ENV-1-RPS_THERMAL_CRITICAL: RPS temperature has reached
critical threshold.
Explanation The temperature sensor value in the RPS 2300 has reached the critical threshold. It
cannot function normally.
Recommended Action The external temperature is too high. Immediately reduce the room
temperature in the room.
Error Message PLATFORM_ENV-1-TEMP: Abnormal temperature detected.
Explanation An abnormal temperature is detected.
Recommended Action Ensure that ambient temperature is not too high. If the message appears again,
check the switch temperature by entering the show env all privileged EXEC command.
Error Message PLATFORM_ENV-2-RPS_THERMAL_WARNING: RPS temperature has reach warning
threshold.
Explanation The temperature sensor value in the RPS 2300 has reached the warning threshold. The
RPS can function normally until the temperature reaches the critical threshold.
Recommended Action The external temperature is high. Reduce the room temperature.
Error Message PLATFORM_ENV-3-RPS_BACKOFF_FAILED: [chars].
Explanation The RPS 2300 is continuing to back up the switch even though the command on the
switch instructs it to no longer provide power to the switch. [chars] is the error message.
Recommended Action No action is required.
Error Message PLATFORM_ENV-3-RPS_CHANGE_TO_STANDBY: [chars].
Explanation The RPS 2300 state changed to standby. It can no longer provide power to the switch.
[chars] is the error message.
Recommended Action No action is required.