Figure 27. Configurator GUI (Ethernet settings window)
To change the ethernet settings, do the following steps:
• To choose the correct data exchange speed for each Ethernet
port, click one of the following data exchange speeds:
• Auto (The data exchange speed for the selected port will
be chosen automatically).
• 10 Mbit half duplex.
• 10 Mbit full duplex.
• 100 Mbit half duplex.
• 100 Mbit full duplex.
7.6.3. Static routes
The Static routes window is used to set static routing rules (in other
words, manually-configured routing entries, as opposed to routing
instructions from a dynamic routing table) for a Fluidmesh unit.
Static routes are typically used if there is a need to do any of the following
in context of the network:
• Access a remote subnet that does not belong to a local network
• Access other Fluidmesh radio units or client devices across the
local network
• Reach gateways (such as Internet gateways)
• Create networks that include 'fixed' devices (such as CCTV
cameras)
To change the Static Routes settings, click the -static routes link under
ADVANCED SETTINGS in the left-hand settings menu.
• The Static Routes dialog will be shown (Figure 28 (page 72)).