DETAILED STEPS
PurposeCommand or Action
Configures the clock manager.
clock protocol protocol vdc vdc-num
Step 1
Example:
# clock protocol ptp vdc 2
The values for the protocol argument are ptp, ntp, and none.
The following describes the values:
• ptp—Synchronizes clocks with Precision Time Protocol (PTP) as described
by IEEE 1588.
• ntp— Synchronizes clocks with Network Time Protocol (NTP).
• none—Use clock set to set supervisor clocks.
When none is used, the clock in the specified VDC must be
configured.
Note
Once the protocol is configured, the clock in the specified VDC must
use that protocol.
For example, if the clock protocol ptp vdc 2 command is entered,
then PTP should be configured in VDC 2.
Note
The range for the vdc argument is 1 to 8.
(Optional)
Displays the configuration of the clock manager.
show run clock_manager
Example:
#show run clock_manager
Step 2
Managing Users
You can display information about users logged into the device and send messages to those users.
Displaying Information about the User Sessions
You can display information about the user session on the device.
SUMMARY STEPS
1.
show users
   Cisco Nexus 5500 Series NX-OS Fundamentals Configuration Guide, Release 7.x
102 OL-30890-01   
Basic Device Management
Managing Users