Power Actual Actual Total
Supply Model Output Input Capacity Status
(Watts ) (Watts ) (Watts )
------- ------------------- ---------- ---------- ---------- -------------
-
1 N9K-PAC-3000W-B 517 W 566 W 3000 W Ok
2 ------------ 0 W 0 W 0 W Absent
3 ------------ 0 W 0 W 0 W Absent
4 N9K-PAC-3000W 0 W 0 W 0 W Shutdown
Actual Power
Module Model Draw Allocated Status
(Watts ) (Watts )
------- ------------------- ----------- ----------- --------------
4 N9k-X9636PQ 177.00 W 399.60 W Powered-Up
22 N9K-C9504-FM-R 118.00 W 300.00 W Powered-Up
24 N9K-C9504-FM-R N/A 0.00 W Powered-Dn
26 N9K-C9504-FM-R N/A 0.00 W Powered-Dn
27 N9K-SUP-B 47.00 W 79.92 W Powered-Up
28 N9K-SUP-B 45.00 W 79.92 W Powered-Up
29 N9K-SC-A 12.00 W 60.00 W Powered-Up
30 N9K-SC-A 23.00 W 60.00 W Powered-Up
fan1 N9K-C9504-FAN 47 W 225.00 W Powered-Up
fan2 N9K-C9504-FAN 48 W 225.00 W Powered-Up
fan3 N9K-C9504-FAN 47 W 249.00 W Powered-Up
N/A - Per module power not available
Power Usage Summary:
--------------------
Power Supply redundancy mode (configured) Non-Redundant(combined
)
Power Supply redundancy mode (operational) Non-Redundant(combined
)
Total Power Capacity (based on configured mode) 3000.00 W
Total Power of all Inputs (cumulative) 3000.00 W
Total Power Output (actual draw) 517.00 W
Total Power Input (actual draw) 566.00 W
Total Power Allocated (budget) 1728.24 W
Total Power Available for additional modules 1271.76 W
switch#
Reload a Module
You can reset a module by using the reload module slot_number command and specifying the module by its
slot number in the chassis.
Reloading a module disrupts traffic through the module.
Caution
To see which slots are filled with modules, use the show inventory command.
Note
Cisco Nexus 9504 NX-OS Mode Switch Hardware Installation Guide
61
Managing the Switch
Reload a Module