Cisco Nexus 9504 - Displaying the Status for the Fan Trays

Cisco Nexus 9504
138 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
When replacing a failed fan tray in a running system, be sure to replace the fan tray promptly.
Note
If one or more fans fail within a fan tray, the Fan Status LED turns red. A fan failure could lead to
temperature alarms if not corrected immediately.
Tip
The software is continuously monitoring the fan status. In a fan failure, the following actions occur:
System messages are displayed.
Call Home alerts are sent (if configured).
SNMP notifications are sent (if configured).
To display the fan module statuses, see Displaying the Status for the Fan Trays, on page 70.
The fan trays fill slots FAN 1, FAN 2, and FAN 3 in the chassis.
Note
Displaying the Status for the Fan Trays
You can display the status of the fan trays by using the show environment fan command.
switch# show environment fan
Fan:
------------------------------------------------------
Fan Model Hw Status
------------------------------------------------------
Fan1(sys_fan1) N9K-C9504-FAN 0.5020 Ok
Fan2(sys_fan2) N9K-C9504-FAN 0.5020 Ok
Fan3(sys_fan3) N9K-C9504-FAN 0.5010 Ok
Fan_in_PS1 -- -- Ok
Fan_in_PS2 -- -- None
Fan_in_PS3 -- -- None
Fan_in_PS4 -- -- None
Fan Zone Speed: Zone 1: 0x0
Fan Air Filter : NotSupported
switch#
If the status is not reported for a fan tray and the status LED is not lit for that installed fan tray, check
to be sure that there is a fabric module that is installed behind the fan tray.
Note
Cisco Nexus 9504 NX-OS Mode Switch Hardware Installation Guide
70
Managing the Switch
Displaying the Status for the Fan Trays