A-12
Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration Guide, R8.0
Appendix A Command Reference
rpr-ieee atd-timer value
rpr-ieee atd-timer value
Use this command to configure the attribute discovery (ATD) timer, which controls the frequency of
ATD packet transmissions on the IEEE 802.17b based RPR interface.
Syntax Description
Defaults Default is 1 second.
Command Modes IEEE 802.17b based RPR interface configuration
Usage Guidelines The ATD timer value is very rarely changed. This is usually done only if other equipment uses a different
ATD value or has processor limitations and cannot handle frames at one per second.
Examples In this example, interface is shortened to int.
router(config)# int rpr-ieee 0
router(config-if)# rpr-ieee atd-timer 1
Related Commands None
Parameter Description
value Value expressed in seconds. Range is 1 through 10.