EasyManua.ls Logo

Cisco UCS C200 M2 - Page 18

Cisco UCS C200 M2
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server
18
CONFIGURING the SERVER
(3) Optional RAID configuration
Select one of the RAID configuration options listed in Table 5.
Caveats
The two optional RAID controllers are half-height PCIe cards. If you choose one of these
optional cards, only the full-height PCIe card slot will be available for adding an optional
PCIe card.
If you choose the mezzanine card, both the half-height and full-height PCIe card slots are
still available for adding optional PCIe cards.
You can choose only one RAID controller (integrated controller, plug-in PCIe controller, or
mezzanine card controller).
You can choose an optional RAID configuration (RAID 0, 1, 5, 1E, 6, or 10), which is
preconfigured at the factory. If you do not choose a RAID configuration, the disks will be
configured as a JBOD.
NOTE: If an optional RAID configuration is not chosen, the disks will be configured as
a JBOD.