EasyManuals Logo
Home>Cisco>Server>UCS C24 M3

Cisco UCS C24 M3 User Manual

Cisco UCS C24 M3
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
Cisco UCS C24 M3 High-Density SFF Rack-Mount Server
46
SUPPLEMENTAL MATERIAL
Low-Voltage DIMM Considerations
The C24 M3 server can be ordered with low-voltage (1.35 V) DIMMs only. Note the following considerations:
Low-voltage DIMMs within the server must have the identical manufacturer, type, speed,
and size.
Low-voltage DIMMs and standard-voltage DIMMs can be mixed in the same server. Note that
this causes the system BIOS to default to standard-voltage operation (Performance Mode).
That is, the server cannot operate in Power Saving Mode unless all DIMMs are low-voltage
DIMMs.
CPUs that have a maximum memory frequency less than 1333 MHz support low-voltage
DIMMs operating in Power Saving Mode only, and do not support Performance Mode.

Other manuals for Cisco UCS C24 M3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco UCS C24 M3 and is the answer not in the manual?

Cisco UCS C24 M3 Specifications

General IconGeneral
BrandCisco
ModelUCS C24 M3
CategoryServer
LanguageEnglish

Related product manuals