EasyManuals Logo

Cisco UCS C240 M3 Specifications

Cisco UCS C240 M3
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
29
Caveats
If you select an internal drive RAID controller, it is installed by default in PCIe slot 4
(half-height) or 3 (full-height); however, you can go into the BIOS and change the option
C240 M3
SFF
16 HDD
2
Not
allowed
Installed
Not
allowed
Not
allowed
Not
allowed
Card
absent
8 internal A A A A A
C240 M3
SFF
16 HDD
2
Not
allowed
Not
allowed
Not
allowed
Installed
slot 4
(default)
Card
absent
Card
absent
8 internal A A A O A
C240 M3
SFF
16 HDD
2
Not
allowed
Not
allowed
Not
allowed
Installed
slot 4
(default)
Installed
slot 3
(default)
Not
allowed
16
internal
9
A A O O A
C240 M3
SFF
16 HDD
2
Not
allowed
Card
absent
Not
allowed
Card
absent
Card
absent
Installed
any slot
0 internal
240
external
A A A A A
C240 M3
SFF
16 HDD
2
Not
allowed
Installed
Not
allowed
Not
allowed
Not
allowed
Installed
any slot
8 internal
240
external
A A A A A
C240 M3
SFF
16 HDD
2
Not
allowed
Not
allowed
Not
allowed
Installed
slot 4
(default)
Not
allowed
Installed
any slot
(except
slot 4)
8 internal
240
external
A A A O A
Notes . . .
1. Embedded RAID is only compatible with the 16 HDD backplane. It cannot be used with the 24 HDD backplane.
2. Never disable OPROM for the mezzanine slot if the mezzanine card is present, or the system will not boot. If you
remove the mezzanine card and disable its OPROM, you can boot from another bootable device (RAID card,
embedded RAID, or from SAN via an HBA or CNA card). When you boot from a device, make sure its OPROM is
enabled, it is in the proper boot sequence, and its BIOS is configured for a bootable device.
3. If you want to boot from a device other than the 9271-8i or 9271CV-8i MegaRAID PCIe card, you can leave the
card installed. Just disable the OPROM for its slot, and the system will boot even with the card installed.
4. External RAID card is the 9285CV-8e or 9286CV-8e. Any of these can be installed simultaneously with either one
mezzanine RAID controller card or one internal RAID controller card (9271-8i or 9271CV-8i).
5. A = available slot, O = occupied slot, U = unsupported slot (slots 4 and 5 are not supported in 1-CPU systems)
6. The mezzanine cards are not supported in 1-CPU systems
7. The OPROM is enabled for the default PCIe RAID controller slots. If you want to enable a different slot, you must
go into the BIOS and enable the OPROM for the desired slot and disable the OPROM for the default PCIe slot (see
Figure 9 on page 74).
8. The mezzanine cards are not supported in 1-CPU systems
9. Two RAID cards are required to control all 16 drives in the C240 SFF 16 HDD backplane system.
Table 9 Supported RAID Configurations
Server
#
CPUs
Embedded
RAID
1
Mezz
RAID
2
NYTRO
MegaRAID
200 RAID
Card
Internal
PCIe RAID
#1
3
Internal
PCIe
RAID #2
External
PCIe
RAID
4
# Drives
Supported
PCIe
Slots
5
1 2 3 4 5

Table of Contents

Other manuals for Cisco UCS C240 M3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco UCS C240 M3 and is the answer not in the manual?

Cisco UCS C240 M3 Specifications

General IconGeneral
Processor cores8
Processor modelE5-2600
Processor frequency2.7 GHz
Number of processors installed2
HDD size2.5 \
RAID supportYes
HDD interface-
Optical drive typeNo
Total storage capacity300 GB
Maximum storage capacity- TB
Number of HDDs installed16
Memory slots24
Internal memory96 GB
Memory clock speed1866 MHz
Internal memory typeDDR3-SDRAM
Maximum internal memory- GB
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
PCI Express x8 slots3
Chassis typeRack (2U)
Power supply650 W
Operating altitude0 - 3000 m
Non-operating altitude0 - 12000 m
Operating temperature (T-T)-40 - 70 °C
Storage relative humidity (H-H)5 - 93 %
Operating relative humidity (H-H)10 - 90 %
Harmonized System (HS) code84714100
Weight and Dimensions IconWeight and Dimensions
Depth712 mm
Width445 mm
Height87 mm

Related product manuals