EasyManuals Logo

Cisco UCS C240 M3 Specifications

Cisco UCS C240 M3
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #41 background imageLoading...
Page #41 background image
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
41
Approved Configurations
(1) GPU Kit
Select a GPU kit to prepare the C240 M3 chassis (V01 chassis version only) for GPU capability.
If you have a newer V02 chassis, you do not need a GPU kit.
(2) GPU Power Cables
When you order one or two GPUs for a V02 chassis version, you also need to order one or two
power cables. Order the “Y” power cable (UCSC-GPUCBL-88Y=) for 2 GPUs and the
“straight” power cable (UCSC-GPUCBL-88S=) for a single GPU.
(3) NVIDIA GRID GPU Slot Population Rules
Table 16 shows the rules for populating NVIDIA GRID K1 or K2 GPU cards in the server.
(4) NVIDIA Tesla GPU Slot Population Rules
Table 17 shows the rules for populating NVIDIA Tesla GPU cards in the server.
CAUTION: When using dual NVIDIA GRID K2 GPU cards, you must preserve
at least 10 mm of space between servers to ensure adequate airflow and cooling.
NVIDIA GRID K1 GPU cards do not require this gap.
CAUTION: When using GRID GPU cards, the operating temperature range is
32° to 95°F (0° to 35°C).
NOTE: Mixing different GPU cards in the same server is not supported.
NOTE: All GPU cards require two CPUs and two 1200 W power supplies in the server.
Table 16 NVIDIA GRID GPU Population Rules by Server Version
C240 M3 Server Version Single K1 GPU Dual K1 GPUs Single K2 GPU Dual K2 GPUs
Server version V01 Slot 5
Slots 2
1
and 5
Notes . . .
1. When a GPU is installed in slot 2, slot 1 is blocked and unavailable for use.
Slot 5 Not supported
Server version V02 Slot 5
Slots 2
1
and 5
Slot 5 Slots 2 and 5

Table of Contents

Other manuals for Cisco UCS C240 M3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco UCS C240 M3 and is the answer not in the manual?

Cisco UCS C240 M3 Specifications

General IconGeneral
Processor cores8
Processor modelE5-2600
Processor frequency2.7 GHz
Number of processors installed2
HDD size2.5 \
RAID supportYes
HDD interface-
Optical drive typeNo
Total storage capacity300 GB
Maximum storage capacity- TB
Number of HDDs installed16
Memory slots24
Internal memory96 GB
Memory clock speed1866 MHz
Internal memory typeDDR3-SDRAM
Maximum internal memory- GB
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
PCI Express x8 slots3
Chassis typeRack (2U)
Power supply650 W
Operating altitude0 - 3000 m
Non-operating altitude0 - 12000 m
Operating temperature (T-T)-40 - 70 °C
Storage relative humidity (H-H)5 - 93 %
Operating relative humidity (H-H)10 - 90 %
Harmonized System (HS) code84714100
Weight and Dimensions IconWeight and Dimensions
Depth712 mm
Width445 mm
Height87 mm