Loading...
22-4
Catalyst 2960 Switch Software Configuration Guide
OL-8603-04
Chapter 22 Configuring UDLD
Configuring UDLD
Configuring UDLD
These sections contain this configuration information:
Default UDLD Configuration, page 22-4
Configuration Guidelines, page 22-4
Enabling UDLD Globally, page 22-5
Enabling UDLD on an Interface, page 22-5
Resetting an Interface Disabled by UDLD, page 22-6
Default UDLD Configuration
Table 22-1 shows the default UDLD configuration.
Configuration Guidelines
These are the UDLD configuration guidelines:
UDLD is not supported on ATM ports.
A UDLD-capable port cannot detect a unidirectional link if it is connected to a UDLD-incapable
port of another switch.
When configuring the mode (normal or aggressive), make sure that the same mode is configured on
both sides of the link.
Caution Loop guard works only on point-to-point links. We recommend that each end of the link has a directly
connected device that is running STP.
Table 22-1 Default UDLD Configuration
Feature Default Setting
UDLD global enable state Globally disabled
UDLD per-port enable state for fiber-optic media Disabled on all Ethernet fiber-optic ports
UDLD per-port enable state for twisted-pair (copper) media Disabled on all Ethernet 10/100 and 1000BASE-TX ports
UDLD aggressive mode Disabled