8. Disassembling “SA, COVER OPEN SENSOR F2”
Remove one “SCREW, BHT (BT#3), M1.7 7” that fastens “SA, COVER OPEN SENSOR F2”.
Detach the cables from the hooks at “FRAME, MAIN-03”.
<Precaution at reassembly>
Be careful not to tighten the
screw excessively.
Check the sensor mounting
position and its orientation.
1-3. Assembly Procedure
When reassembling the parts, follow the procedure of “1-2 Disassembly Procedure” in reverse.
SCREW, PHT (BT#3), M1.7 7