EasyManua.ls Logo

ClimateMaster Tranquility TTH072 Series User Manual

ClimateMaster Tranquility TTH072 Series
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Tranquility
®
30
(TT) Series
Models TTD/H/V 026 - 072
60 Hz - HFC-410A
INSTALLATION, OPERATION,
& MAINTENANCE
97B0075N05
Revised: 18 July, 2013
Table of Contents
Model Nomenclature 3
Unit Physical Data 6
Horizontal Installation 7
Field Conversion of Air Discharge 9
Horizontal Installation 10
Vertical Installation 11
Piping Installation 13
Water-Loop Heat Pump Applications 14
Ground-Loop Heat Pump Applications 15
Ground-Water Heat Pump Applications 17
Water Quality Standards 19
Electrical - Line Voltage 20
Electrical - Power Wiring 22
Electrical - Power & Low Voltage Wiring 23
Electrical - Low Voltage Wiring 24
Electrical - Thermostat Wiring 26
Blower Performance Data 27
ECM Blower Control 28
Typical Wiring Diagram - Units with CXM Board
and ECM Fan Motor (Single Phase) 30
Typical Wiring Diagram - Units with
ClimaDry
®
(Single Phase) 31
Typical Wiring Diagram - Units with CXM Board, 32
ECM Fan Motor, and MPC (DDC) CONTROLS
(SINGLE PHASE) 32
CXM Controls 33
DXM Controls 34
Safety Features - CXM and DXM Controls 36
ClimaDry
®
Modulating Reheat Option 38
Unit Starting and Operating Conditions 41
Piping System Cleaning and Flushing 42
Unit and System Checkout 44
Unit Start-Up Procedure 45
ClimaDry
®
II Option Corrections
(When Operating in Non-ClimaDry
®
Mode) 46
Unit Operating Conditions 47
Preventive Maintenance 49
Functional Troubleshooting 50
Performance Troubleshooting 51
Start-Up Log Sheet 52
Functional Troubleshooting 53
Warranty (U.S. & Canada) 54
Warranty (International) 55
Revision History 56

Questions and Answers:

ClimateMaster Tranquility TTH072 Series Specifications

General IconGeneral
TypeWater Source Heat Pump
RefrigerantR-410A
Compressor TypeScroll
Voltage208-230V
Phase3
ModelTTH072

Summary

Model Nomenclature

General Information

Safety

Provides warnings, cautions, and notices for installation, service, and troubleshooting.

Pre-Installation Procedures

Horizontal Installation

Mounting Horizontal Units

Instructions for suspending horizontal units using hanger kits and vibration isolators.

Horizontal Installation Details

Duct System Installation

Emphasizes proper duct sizing, design, and connections for unit performance and noise reduction.

Field Conversion of Air Discharge

Side to Back Discharge Conversion

Provides step-by-step instructions for converting the air discharge from side to back.

Horizontal Installation Piping

Condensate Piping

Details requirements for condensate drain lines, pitching, traps, and venting for horizontal units.

Vertical Installation

Vertical Installation Details

Condensate Piping for Vertical Units

Explains condensate piping for vertical units, noting internal trap and no external trap needed.

Piping Installation

Supply and Return Piping Guidelines

Guidelines for installing supply and return piping, including valves, strainers, and hose length.

Water-Loop Heat Pump Applications

Commercial Water Loop Applications

Describes commercial systems connected to common piping, insulation, and hose kits.

Ground-Loop Heat Pump Applications

Ground Loop Piping Installation

Details typical closed loop ground source system, materials, and pressure testing.

Water Quality Standards

Open Loop Ground Water Systems

Describes open loop piping, shut off valves, P/T plugs, and material compatibility for ground water systems.

Ground-Water Heat Pump Applications

Electrical - Line Voltage

General Line Voltage Wiring

Instructions for matching available power to unit specifications and following codes.

Electrical - Power Wiring

Power Connection Procedure

Details line voltage connection to the contactor side and consulting electrical data for fuse size.

Electrical - Power & Low Voltage Wiring

Electrical - Low Voltage Wiring

Thermostat Connections

Details thermostat wiring to the ECM control board or terminal block, referring to diagrams.

Electrical - Thermostat Wiring

Thermostat Installation Guidelines

Guidelines for thermostat placement, wall mounting, and wiring, emphasizing 18 AWG wire.

ECM Blower Control

Wiring Diagrams

CXM Board with ECM Fan Motor

Typical wiring diagram for units with CXM board and ECM fan motor (single phase).

Units with ClimaDry®

Typical wiring diagram for units with ClimaDry® (single phase).

CXM Board, ECM, MPC (DDC) Controls

Typical wiring diagram for units with CXM, ECM, and MPC (DDC) controls (single phase).

Control System Operations

CXM Controls

Details CXM control features including test mode, configuration options, and DIP switches.

DXM Controls

Details DXM control features including test mode, configuration options, DIP switches, and accessories.

Control Safety Features

ClimaDry® Modulating Reheat Option

ClimaDry® Sequence Of Operation

Details the three operating modes (cooling, cooling with reheat, heating) and thermostat compatibility.

UNIT STARTING AND OPERATING CONDITIONS

Piping System Cleaning and Flushing

Piping System Cleaning and Flushing Procedure

Provides step-by-step instructions for cleaning and flushing the WLHP piping system.

Flushing/Purging Units with ClimaDry®

Unit and System Checkout

Unit Start-up Procedure

Preventive Maintenance

Functional Troubleshooting

Performance Troubleshooting

Functional Troubleshooting Analysis

Warranty (U.S. & Canada)

Warranty (International)

Related product manuals