ClimateMaster Tranquility TTH072 Series - Model Nomenclature

ClimateMaster Tranquility TTH072 Series
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
climatemaster.com
THE SMART SOLUTION FOR ENERGY EFFICIENCY
Tranquility
®
30 (TT) Series
Rev.: 07/18/13
026 = “E, F, G, H”
072 = “F, G, H”
038 = “F, G, H”
049 = “F, G, H”
064 = “F, G, H”
}
A0 2 6 CG 1 0 A L K
4 5 6 7
8
91011121314
UNIT SIZE
RETURN AIR FLOW CONFIGURATION
VOLTAGE
CONTROLS
REVISION LEVEL
HEAT EXCHANGER OPTIONS
SUPPLY AIR FLOW &
MOTOR CONFIGURATION
TT
1 2
TT = Tranquility
®
Two Stage Scroll
SERIES
V
3
V = Vertical Up
CONFIGURATION
Standard
Motorized Valve
Non Coated Air Coil
Copper
Cupro-Nickel
Copper
Cupro-Nickel
C
T
N
S
A
U
J
W
L = Left Return
R = Right Return
0 = None
WATER CIRCUIT OPTIONS
2 = HWG (Coil Only)
6 = HWG (Coil Only) w/Auto Flow Regulator 2.5 GPM/Ton
7 = HWG (Coil Only) w/Auto Flow Regulator 3.0 GPM/Ton
8 = Auto Flow Regulator 2.5 GPM/Ton
9 = Auto Flow Regulator 3.0 GPM/Ton
S
15
S = Standard
STANDARD
H = Horizontal
D = Vertical Down
5 = Internal Secondary Pump
Supply
Configuration
Motor
KTTV
NTTD
PTTH
WTTH
Top
Down
Back
Straight
ECM
ECM
ECM
ECM
ClimaDry
®
EPDF
Tin Plated Air Coil
D = DXM
L= CXM w/LON
M = DXM w/LON
P = DXM w/MPC
B = DXM
K = DXM w/LON
S = DXM w/MPC
w/
Disconnect
C = CXM
N = CXM w/MPC
A = CXM
E = CXM w/LON
R = CXM w/MPC
G = 208-230/60/1
H = 208-230/60/3
E = 265/60/1
F = 460/60/3
Cabinet Insulation
OPTION
1
A
J
K
2
C
L
M
3
E
N
P
1” FILTER
RAIL
RANGE
ULTRA
QUIET
2” FILTER
RAIL
1” FILTER
FRAME
2” FILTER
FRAME
4
G
R
S
NO
YES
NO
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
B = Current 026, 049 - 072
C = Current 038
Model Nomenclature
Note: Above model nomenclature is a general reference. Consult individual engineering guides for
detailed information.
ClimaDry
®
II Option Notes:
1. Unit must have DXM control option. 460 volt unit units require a four wire power supply with neutral.
2. ClimaDry
®
II may not be combined with motorized water valve, internal secondary circulating pump, or automatic
ow regulator options.
3. Unit minimum entering air temperature while in the dehumidi cation, cooling, or continuous fan modes is
70ºF DB/61ºF WB. Operation below this minimum may result in nuisance faults.
4. A thermostat with dehumidi cation mode or thermostat and separate humidistat/dehumidistat is required for
activation and control of ClimaDry
®
II.
5. Down ow and 575 volt units are not eligible for ClimaDry
®
II.