EasyManua.ls Logo

ClimateMaster Tranquility TY Series - Page 40

ClimateMaster Tranquility TY Series
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Tranquility
®
22
(
TY
)
Series
Rev.: July 8, 2021
ClimateMaster Water-Source Heat Pumps
40
CLIMATEMASTER WATER-SOURCE HEAT PUMPS
Unit Operating Conditions, Cont’d.
024 Full Load Cooling - without HWG active Full Load Heating - without HWG active
Entering
Water
Temp °F
Water
Flow
GPM/ton
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Superheat Subcooling
Water
Temp Drop
°F
Air Temp
Drop °F
DB
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Superheat Subcooling
Water
Temp Drop
°F
Air Temp
Rise °F
DB
30*
1.5
2.25
3
67-77
72-82
77-87
297-317
303-323
309-329
1-6
3-8
3-8
2-7
5-10
5-10
8.0-10.0
5.9-7.9
3.8-5.8
18-23
20-25
21-27
50
1.5
2.25
3
127-137
125-135
124-134
244-264
205-225
166-186
8-12
8-12
10-15
9-14
7-12
5-10
20.6-22.6
14.5-16.5
8.41-10.41
19-25
19-25
19-25
98-108
104-114
111-121
340-360
343-363
346-366
6-11
6-11
8-12
5-10
5-10
5-10
11.1-13.1
8.1-10.1
5.2-7.2
24-27
26-31
27-32
70
1.5
2.25
3
132-142
131-141
130-140
327-347
301-321
276-296
8-12
8-12
8-12
11-16
9-14
7-12
19.9-21.9
14.0-16.0
8.0-10.0
18-24
18-24
18-24
129-139
137-147
145-155
373-393
390-410
401-421
10-15
11-16
11-16
5-10
5-10
5-10
14.4-16.4
10.5-12.5
6.5-8.5
30-35
33-40
33-36
90
1.5
2.25
3
140-150
139-149
138-148
457-477
433-453
409-429
6-11
6-11
6-11
13-18
11-16
9-14
19.9-21.9
13.2-15.2
7.5-9.5
17-23
17-23
17-23
162-172
170-180
178-188
406-426
415-435
423-443
14-19
14-19
14-19
3-8
3-8
3-8
17.5-19.5
12.7-14.7
7.9-9.9
36-41
37-41
38-43
110
1.5
2.25
3
144-154
143-153
143-153
530-550
510-530
490-510
4-10
4-10
4-10
13-18
13-18
11-16
18.9-20.9
13.0-15.0
7.11-9.11
16-22
16-22
16-22
*Based on 15% Methanol antifreeze solution
036 Full Load Cooling - without HWG active Full Load Heating - without HWG active
Entering
Water
Temp °F
Water
Flow
GPM/ton
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Superheat Subcooling
Water
Temp Drop
°F
Air Temp
Drop °F
DB
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Superheat Subcooling
Water
Temp Drop
°F
Air Temp
Rise °F
DB
30*
1.5
2.25
3
60-70
65-75
70-80
315-335
321-341
327-347
4-9
5-10
6-11
11-16
11-16
11-16
10.0-12.0
6.7-8.7
3.4-5.4
18-23
19-24
20-25
50
1.5
2.25
3
123-133
122-132
121-131
244-264
240-260
235-255
10-15
10-15
11-16
12-17
9-14
7-12
20.9-22.9
14.3-16.3
7.8-9.8
17-22
17-22
17-22
88-98
96-106
105-115
353-373
361-381
370-390
6-11
8-13
9-14
12-17
12-17
12-17
13.2-15.2
9.0-11.0
4.8-6.8
24-29
25-30
26-31
70
1.5
2.25
3
128-138
124-134
119-129
328-348
300-320
273-293
8-13
9-14
9-14
12-17
10-15
9-14
20.2-22.2
13.8-15.8
7.5-9.5
16-21
16-21
16-21
116-126
128-138
139-149
390-410
400-420
411-431
9-14
11-16
13-18
12-17
10-15
10-15
17.0-19.0
11.6-13.6
6.1-8.1
29-34
31-36
32-37
90
1.5
2.25
3
135-145
134-144
132-142
453-473
428-448
402-422
7-12
7-12
8-13
13-18
11-16
9-14
19.2-21.2
13.1-15.1
7.1-9.1
16-21
15-20
14-19
148-158
160-170
173-183
424-444
439-459
453-473
12-17
14-19
16-21
9-14
9-14
8-13
20.9-22.9
14.2-16.2
7.4-9.4
35-40
37-42
39-44
110
1.5
2.25
3
139-149
138-148
137-147
525-545
503-523
480-500
6-11
6-11
6-11
14-19
12-17
10-15
18.5-20.5
12.7-14.7
6.9-8.9
13-18
13-18
14-19
*Based on 15% Methanol antifreeze solution
030 Full Load Cooling - without HWG active Full Load Heating - without HWG active
Entering
Water
Temp °F
Water
Flow
GPM/ton
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Superheat Subcooling
Water
Temp Rise
°F
Air Temp
Drop °F
DB
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Superheat Subcooling
Water
Temp Drop
°F
Air Temp
Rise °F
DB
30*
1.5
2.25
3
65-75
67-77
72-82
311-331
315-335
319-339
9-14
9-14
9-14
9-14
9-14
9-14
8.0-10.0
6.2-8.2
4.3-6.3
19-24
20-25
21-26
50
1.5
2.25
3
122-132
121-131
121-131
240-260
213-233
186-206
10-15
11-16
11-16
11-16
9-14
7-12
19.5-21.5
15.0-17.0
10.3-12.3
18-23
19-24
19-24
95-105
100-110
105-115
353-373
358-378
362-382
11-16
11-16
12-17
10-15
10-15
10-15
10.5-12.5
8.2-10.2
5.8-7.8
26-31
26-31
27-32
70
1.5
2.25
3
122-132
121-131
121-131
316-336
298-318
280-300
9-14
9-14
9-14
12-17
11-16
9-14
18.8-20.8
14.3-16.3
9.8-11.8
17-22
17-22
17-22
124-134
130-140
137-147
390-410
398-418
405-425
13-18
14-19
15-20
10-15
9-14
9-14
13.5-15.5
10.5-12.5
7.5-9.5
33-38
33-38
34-39
90
1.5
2.25
3
133-143
133-143
132-142
438-458
420-440
401-421
8-13
8-13
8-13
14-19
13-18
11-16
17.8-19.8
13.5-15.5
9.2-11.2
15-20
15-20
15-20
156-166
163-173
170-180
430-450
459-479
448-468
16-21
17-22
18-23
8-13
8-13
8-13
16.5-18.5
12.8-14.8
9.0-11.0
37-42
39-44
40-45
110
1.5
2.25
3
137-147
136-146
135-145
507-527
490-510
473-493
6-11
7-12
7-12
16-21
14-19
13-18
17.2-19.2
13.0-15.0
8.8-10.8
15-20
15-20
15-20
*Based on 15% Methanol antifreeze solution
Table 11: TY Series Typical Unit Operating Pressures and Temperatures (60Hz – I-P Units)

Related product manuals