EXAMPLE COMMAND (ASCII) COMMAND (HEX)
Set level in
Zone 2 to
-12 dB
<Z2.MU,L12/>
3C 5A 32 2E 4D 55
2C 4C 31 32 2F 3E
Reduce level
in Zone 1 by
10 dB
<Z1.MU,LD10/>
3C 5A 31 2E 4D 55
2C 4C 44 31 30 2F
3E
Increase level
in Zone 2 by
6 dB
<Z2.MU,LU6/>
3C 5A 32 2E 4D 55
2C 4C 55 36 2F 3E
3. Mute/Unmute Mics
The 24 Series mixer-amplier’s mic input may be enabled or
disabled. This may be done on a per-zone basis or globally
(both zones).
EXAMPLE COMMAND (ASCII) COMMAND (HEX)
Mute mic in
Zone 2 only
<Z2.M1,M/>
3C 5A 32 2E 4D 31
2C 4D 2F 3E
Unmute mic
in Zone 2 only
<Z2.M1,O/>
3C 5A 32 2E 4D 31
2C 4F 2F 3E
Mute mic
globally
<MI,M/>
3C 4D 49 2C 4D 2F
3E
Unmute mic
globally
<MI,O/>
3C 4D 49 2C 4F 2F
3E