MAN.219 Rev.8 ENG - Use and maintenance manual S19N page 30 of 71
5. At the end of the operations, reset the original conditions of all cur-
sors and taps manipulated.
It is strictly forbidden to use the MEWP with solenoid valves
tampered or without seals.
It is mandatory to restore all the sealings after use of these
items.
AFTER THE RECOVERY OF THE PLATFORM, BRING THE
MEWP TO C.M.C. OR TO AN AUTHORISED WORKSHOP FOR
THE RESTORING OF THE NORMAL OPERATING CONDITIONS
WHICH ARE INDISPENSABLE FOR A SAFETY USE OF THE
MACHINE.
4.6.6 Electropump (*optional)
The 12 V emergency electropump (Picture 23) is an alternative source of
energy for the engine and should be used only in case of emergency.
ANY DIFFERENT USE IS NOT RECOMMENDED BECAUSE,
ABSORBING CURRENT DIRECTLY FROM BATTERIES, IT
COULD PRODUCE THEIR UNEXPECTED DISCHARGE.
Picture 23: electropump.
It can be activated by:
o red activation button (Picture 24) on the left side of the basket
control station;
o sealed activation lever (Picture 24) at the bottom of the turret
box.