MAN.219 Rev.8 ENG - Use and maintenance manual S19N page 54 of 71
Picture 80: remote connection system.
Following the remote connection procedure:
1. Ensure that the M12 socket on the remote connection box is cor-
rectly connected to the M12 plug of the electric box mounted on
the chassis;
2. Share your internet wireless network with the remote connection
device in free mode (without password);
3. Lift the connection remote switch on the chassis box
the led on the remote connection box makes two red
flashes,
after 30 seconds, the led becomes fixed and green, to
show that the operating system is working,
it automatically hooks up to your free network;
4. Install on your PC the TeamViewer software (11
th
version) to con-
nect to the machine system, through ID and Password supplied by
the manufacturer;
5. Call C.M.C. Service for technical assistance.
9 Troubleshooting 
Drawback: THE CONSENT LIGHT FOR STABILIZATION DOES NOT
TURN ON.
Causes: 1. The aerial part of the MEWP is not in transport position.
2. Failure fuse 30A battery side.
3. Defective board.
4. Wire removed from the battery.
Remedies: 1. Place the aerial part of the MEWP in transport position.
2. Check if any cable is disconnected from the battery.
3. Replace fuse.
4. Replace the limit switches.
If the problem persists, contact the Service.
__________________________________________________________
Drawback: THE STABILIZERS DO NOT WORK.
Causes: 1. The hydraulic pump unit is faulty.
2. Stabilizers solenoid valve do not work.
Remedies: 1. Replace the hydraulic pump.
2. Replace the stabilizers limit switches.
If the problem persists, contact the Service.
___________________________________________________________
Drawback: WITH THE MEWP STABILIZED, THE CONSENT LIGHT FOR
AERIAL PART USE DOES NOT TURN ON.
Cause: 1. The green light does not work.
2. Micro-switch system does not work.
3. Stabilization is incomplete.

Related product manuals