EasyManua.ls Logo

CMOSTEK CMT2300A - CMT2300 A Electrical Characteristics; Recommended Operation Condition; Absolute Maximum Rating

CMOSTEK CMT2300A
25 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AN146
Rev 0.9 | Page 4/25
www.cmostek.com
1. Duty-Cycle Operation Mode
1.1 Duty-Cycle Mode Related Register
The corresponding RFPDK interface and parameters are as below:
Figure 1. Duty-Cycle RFPDK Interface
Table 2. Duty-Cycle Related Parameter
Register Bit RFPDK Parameter
Register Bit
Rx Duty-Cycle
RX_DC_EN
Tx Duty-Cycle
TX_DC_EN
Sleep Timer
SLEEP_TIMER_EN
Sleep Time
SLEEP_TIMER_M<10:0>
SLEEP_TIMER_R<3:0>
Rx Timer
RX_TIMER_EN
Rx Time T1
RX_TIMER_T1_M<10:0>
RX_TIMER_T1_R<3:0>
Rx Time T2
RX_TIMER_T2_M<10:0>
RX_TIMER_T2_R<3:0>
Rx Exit State
RX_EXIT_STATE<1:0>
Tx Exit State
TX_EXIT_STATE<1:0>
LFOSC Calibration
LFOSC_RECAL_EN
LFOSC_CAL1_EN
LFOSC_CAL2_EN
XTAL Stable Time
XTAL_STB_TIME<2:0>
The contents and explanations of the register can be seen in the following table.
Table3. Register Located in the Configuration Bank:
Register
Name
Bits
R/W
Bit Name
Function Description
CUS_SYS2
(0x0D)
7
RW
LFOSC_RECAL_EN
Enable LFOSC recalibration 1. Before you
enter the RX or TX every time, if you find the
last result of the calibration 2 beyond the
boundary, that is not to tune the frequency by
the fine adjustment, the calibration 1 can
automatically run again, This calibration will

Other manuals for CMOSTEK CMT2300A

Related product manuals