EasyManuals Logo

CO/Tech MPPH-08CRN1-QB6G1 User Manual

CO/Tech MPPH-08CRN1-QB6G1
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
15
ENGLISH
If theair conditioner is not to be used for alongtime
1. Unscrew thecover over thedrain hole (4), pull therubber plug out of thedrain
hole and connect theincluded drain hose (11). Movetheair conditioner close to
asuitable drain and unscrew thecover over thelower drain hole (8). Makesure
that all water runsout.
2. Turn on thefan (FAN mode) in order to dry theinternal parts of theair conditioner
and hinder mould growth. Letthefan run for about 6hours.
3. Turn off theair conditioner and unplug it from thewall socket.
4. Remove thebatteries from theremote control.
5. Clean theair filter and refitit.
6. Remove thehose from theupper drain outlet.
7. Screw thecovers over thedrain holes backon.
Troubleshootingguide
Theair conditioner
will notstart.
Is it plugged into awall socket?
Is thewall socketlive?
Does error code “P1” appear on thedisplay? Ifthis is
thecase remove thelower drain cover (8). Makesure that
all water drainsout.
Theroom temperature is lower than theset temperature.
Adjust thetemperature using [ TEMP ].
Insufficient cooling. Open windows or doors are allowing warm airin. Closeall
windows anddoors.
There are other sources of heat present in theroom.
Turntheseoff.
Theexhaust hose is not attached. Seethe Connecting
theexhaust hose section.
Thetemperature is set toohigh. Reduce thetemperature.
Theair filter is clogged. SeetheCare and maintenance –
Cleaning thefilter sectionabove.
Noise and
vibrationsoccur.
Make sure that theair conditioner is placed on asteady,
evenand level surface.
Agurgling sound
isheard.
This can often be explained by themovement of thecoolant
in theair conditioner. Thisis completely normal.
Error code E1 Thetemperature control sensor is out of service. Turnoff
theair conditioner, pull out theplug and plug it inagain. Ifthis
does not solve theproblem and theerror code appears
again, contact aqualified service technician.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CO/Tech MPPH-08CRN1-QB6G1 and is the answer not in the manual?

CO/Tech MPPH-08CRN1-QB6G1 Specifications

General IconGeneral
BrandCO/Tech
ModelMPPH-08CRN1-QB6G1
CategoryAir Conditioner
LanguageEnglish