25 OPERATORS MANUAL VITRO LINE
(b) Temperature probe fault
(c) MPU Board fault
(d) Short on solid state relay
(b) Replace probe
(c) Replace MPU board
(d) Replace relay
(a) Probe open circuit
(b) Inlet valve fault
(c) Level probe incorrectly
positioned
(a) Check probe circuit
(b) Check inlet valve and
replace if necessary
(c) Reposition probe
(a) Extractor fan fault
(b) Steam hoods missing from
mixing bowls or incorrectly
positioned
(d) Overflow pipe incorrectly
fitted
(a) Check fan
(b) Fit steam hoods to mixing
bowls and position correctly.
(a) Dispense pipes incorrectly
fitted to dispense head
(b) Mixing bowls incorrectly
fitted
(c) Whipper seals missing
(a) Reposition pipes
(b) Reposition mixing bowls
(c) Check seals
(d) Refit overflow pipe
(a) Display connector loose
(a) Thermal cut-out tripped
(b) Heater fuse blown
(c) Incorrect temperature
setting
(a) Reset cut-out
(b) Check fuse
(c) Check program setting
(a) Vend count has reached
number of vends needed to
trigger error
(a) Press STAR key, then up to
GROUT BIN, then ENTER
to reset
(a) Vend count has reached
number of vends needed to
trigger error
(a) Press STAR key, then up to
ESPRESSO CLEAN, then
ENTER to reset