Page 18 800 Series
Reading Audit Information
Single-/Four-Price and Protocol A Models Only
By reading Audit Information, you can gain
valuable information about your vendor’s
performance. Audit information is retrieved via
the Digital Display by performing the following
steps:
1. Enter the Display Mode (see “Display
Mode” section of this manual).
2. Press C. In response, the display will show
Address “d000”.
3. Press B or D to scroll to the desired audit
address (see Audit Information Addresses).
4. Press C to view the upper four digits of the
displayed address. Press C again to view the
lower four digits, including the decimal point
(if any). EXAMPLE: 10,480.20 would be
displayed as 0104 in the upper four digits
followed by 80.20 in the lower four digits.
5. Press C again to return to the Address
Display.
6. Press A to exit to the “FULL/FILL AbCd”
message.
NOTE: Audit Information is “read only” it can
only be reset using Coinco Support software. or
if address C049 is enabled (Use address C050
to clear audit data)
NOTE: Free vends issued directly from the
vending machine are not audited by the
changer.
SECTION 3: CONFIGURATION
Tube Counts
By briefly depressing and releasing an inventory
button, you can obtain information about the coin
value and the quantity of coins within the tube.